Driver for that regulator is used only in SPL and it uses old I2C
interface. If we want to use DM I2C in U-Boot proper, compilation of
this driver has to be limited only to SPL.
Signed-off-by: Jernej Skrabec <jernej.skrabec@siol.net>
Reviewed-by: Heiko Schocher <hs@denx.de>
Signed-off-by: Maxime Ripard <maxime.ripard@free-electrons.com>
The R40 SoC uses the AXP221s in I2C mode to supply power.
Some regulator's common usages have changed, and also the recommended
voltage for existing usages have changed. Update the defaults to match.
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
The Allwinner H5 is very close to the H3 SoC, but has ARMv8 cores.
To allow sharing the clocks, GPIO and driver code easily, create an
architecture agnostic MACH_SUNXI_H3_H5 Kconfig symbol.
Rename the existing symbol to MACH_SUNXI_H3_H5 where code is shared and
let it be selected by a new shared Kconfig option.
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
The execution flow is currently like this for aldo_num == 1 or 2:
int axp_set_aldo(int aldo_num, unsigned int mvolt)
{
...
if (mvolt == 0)
return pmic_bus_clrbits(AXP809_OUTPUT_CTRL1,
AXP809_OUTPUT_CTRL1_ALDO1_EN << (aldo_num - 1));
...
return pmic_bus_clrbits(AXP809_OUTPUT_CTRL1,
AXP809_OUTPUT_CTRL1_ALDO1_EN << (aldo_num - 1));
}
I.e. aldo1 and aldo2 will always be disabled. This patch fixes it by
setting (rather than clearing) the enable bit when mvolt != 0.
Signed-off-by: Rask Ingemann Lambertsen <rask@formelder.dk>
Fixes: 795857df41 ("sunxi: power: add AXP809 support")
Add the max8997 controller for Driver model.
Exynos4210 is using max8997 pmic controller.
(pmic_max8997.c should be deprecated.)
Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
The array indices used currently are dispalaced by 1 for
SMPS6 through SMPS10 in the respective places of voltage and ctrl
arrays hence fix the same as to assign the right voltage and ctrl
registers.
Signed-off-by: Keerthy <j-keerthy@ti.com>
At present devices use a simple integer offset to record the device tree
node associated with the device. In preparation for supporting a live
device tree, which uses a node pointer instead, refactor existing code to
access this field through an inline function.
Signed-off-by: Simon Glass <sjg@chromium.org>
This patch adds a simple pmic driver for the mc34vr500 pmic which
is used in conjunction with the fsl T1 and LS1 series SoC.
Signed-off-by: Hou Zhiqiang <Zhiqiang.Hou@nxp.com>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
Reviewed-by: York Sun <york.sun@nxp.com>
The variable ret was added but never set as we did not make calls to
other functions that we needed to check the return value on.
Fixes: 505cf4750a ("power: change from meaningless value to error number")
Signed-off-by: Tom Rini <trini@konsulko.com>
'-1' is absolutely meaningless value.
This patch changed from meaningless value to error number.
Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Add support to handle enable-active-high DT property. This property is
used to drive the gpio controlling fixed regulator as active high when
claiming gpio line.
Signed-off-by: Vignesh R <vigneshr@ti.com>
Acked-by: Simon Glass <sjg@chromium.org>
Add the max8998 controller for Driver model.
Samsung S5P series are using max8998 pmic controller.
In future, it should be supported the regulator framework.
Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com>
Signed-off-by: Minkyu Kang <mk7.kang@samsung.com>
Palmas driver assumes it is always TPS659xx regulator on all DRA7xx based
boards to enable mmc regulator. This is not true always like in case of
DRA71x-evm. So get this information based on the board.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Signed-off-by: Vignesh R <vigneshr@ti.com>
Signed-off-by: Nishanth Menon <nm@ti.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
[trini: Delete omap4_vmmc_pbias_config from omap_hsmmc.c]
Signed-off-by: Tom Rini <trini@konsulko.com>
CONFIG_AM57XX is just an unnecessary macro that is redundant given So,
remove the same instead of spreading through out the u-boot source
code and getting in the way to maintain common code for DRA7x family.
Acked-by: Andrew F. Davis <afd@ti.com>
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
Currently the specific set ops functions are directly
called without any check for min/max current limits for a regulator.
Check for them and proceed.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Fixed checking of current limits:
Signed-off-by: Simon Glass <sjg@chromium.org>
Currently the specific set ops functions are directly
called without any check for voltage limits for a regulator.
Check for them and proceed.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Fixed checking of voltate limits:
Signed-off-by: Simon Glass <sjg@chromium.org>
In case we want to force a particular value on a regulator
irrespective of the min/max constraints for testing purposes
one can call regulator_set_value_force function.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Commit a85362fb3e refactored the code
but the register read ended up in the wrong if branch.
Currently, the else branch checks a variable which is always 0.
Signed-off-by: Nicolae Rosia <nicolae_rosia@mentor.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
The signature for this macro has changed. Bring in the upstream version and
adjust U-Boot's usages to suit.
Signed-off-by: Simon Glass <sjg@chromium.org>
Update to drivers/power/pmic/palmas.c:
Signed-off-by: Keerthy <j-keerthy@ti.com>
Change-Id: I6cc9021339bfe686f9df21d61a1095ca2b3776e8
The driver provides regulator set/get voltage
enable/disable functions for lp873x family of PMICs.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
The driver provides regulator set/get voltage
enable/disable functions for palmas family of PMICs.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Tom Rini <trini@konsulko.com>
Add support to bind the regulators/child nodes with the pmic.
Also adds the pmic i2c based read/write funtions to access pmic
registers.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Tom Rini <trini@konsulko.com>
Add support for gpio regulators. As of now this driver caters
to gpio regulators with one gpio. Supports setting voltage values to gpio
regulators and retrieving the values.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
According to the binding documentation the fixed regulator enable GPIO
is optional. However so far registration thereof failed if no enable
GPIO was specified. Fix this by making it entirely optional whether an
enable GPIO is used.
Signed-off-by: Marcel Ziswiler <marcel.ziswiler@toradex.com>
Acked-by: Stephen Warren <swarren@nvidia.com>
Signed-off-by: Tom Warren <twarren@nvidia.com>
Add device model enabled PMIC driver for Ricoh RN5T567 PMIC used
on Colibri iMX7.
Signed-off-by: Stefan Agner <stefan.agner@toradex.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
add driver support for pwm regulator.
Signed-off-by: Elaine Zhang <zhangqing@rock-chips.com>
Signed-off-by: Kever Yang <kever.yang@rock-chips.com>
Acked-by: Simon Glass <sjg@chromium.org>
Now, arch/${ARCH}/include/asm/errno.h and include/linux/errno.h have
the same content. (both just wrap <asm-generic/errno.h>)
Replace all include directives for <asm/errno.h> with <linux/errno.h>.
Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
[trini: Fixup include/clk.]
Signed-off-by: Tom Rini <trini@konsulko.com>
When cold-booting the ldoio0/1 regulators are always off / the
gpios are always at tristate. But when re-booting from android these
are sometimes on. Disable them at axp_init time (iow as early as possible)
to remove this difference between a cold boot and a reboot.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Ian Campbell <ijc@hellion.org.uk>
When enabling a fixed regulator, it may take some time to rise to the
correct voltage. If we do not delay here then subsequent operations
will fail.
Signed-off-by: John Keeping <john@metanate.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
In Tegra186, SoC power domains are manipulated using IPC requests to
the BPMP (Boot and Power Management Processor). This change implements a
driver that does that.
Signed-off-by: Stephen Warren <swarren@nvidia.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Signed-off-by: Tom Warren <twarren@nvidia.com>
The voltage and control registers need to be looked up from the value in
driver_data. Adjust the get_value and get_enable functions to match the
corresponding set_* functions.
Signed-off-by: John Keeping <john@metanate.com>
Acked-by: Simon Glass <sjg@chromium.org>
Linux stopped the use of keyword 'boolean' in Kconfig.
Refer to commit 6341e62b212a2541efb0160c470e90bd226d5496 ("kconfig:
use bool instead of boolean for type definition attributes")
in Linux Kernel.
Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
Many SoCs allow power to be applied to or removed from portions of the SoC
(power domains). This may be used to save power. This API provides the
means to control such power management hardware.
Signed-off-by: Stephen Warren <swarren@nvidia.com>
Acked-by: Simon Glass <sjg@chromium.org>
Quite a few places have a bind() method which just calls dm_scan_fdt_dev().
We may as well call dm_scan_fdt_dev() directly. Update the code to do this.
Signed-off-by: Simon Glass <sjg@chromium.org>
The A80 uses the AXP809 as its primary PMIC.
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Adds poweroff support for axp818 pmic.
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
The AXP818 has a switchable output, SW. This is commonly used for
controlling power to the LCD backlight.
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Description said eldo2 instead of fldo2, a copy-paste error.
Fixes: 38491d9c65 ("power: axp818: Add support for FLDOs")
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>