The current name is inconsistent with SPL which uses CONFIG_SPL_TEXT_BASE
and this makes it imposible to use CONFIG_VAL().
Rename it to resolve this problem.
Signed-off-by: Simon Glass <sjg@chromium.org>
This converts the following to Kconfig:
CONFIG_SYS_SPL_MALLOC_SIZE
CONFIG_SYS_SPL_MALLOC_START
We introduce a default value here as well, and CONFIG_SYS_SPL_MALLOC to
control if we have a malloc pool or not.
Signed-off-by: Tom Rini <trini@konsulko.com>
Update the Kconfig entry to have the correct defaults for i.MX6
platforms, and move the existing large comment from imx6_spl.h to
doc/imx/common/imx6.txt so that it's not lost.
Signed-off-by: Tom Rini <trini@konsulko.com>
This converts the following to Kconfig:
CONFIG_USE_BOOTCOMMAND
CONFIG_BOOTCOMMAND
CONFIG_RAMBOOTCOMMAND
CONFIG_NFSBOOTCOMMAND
Signed-off-by: Tom Rini <trini@konsulko.com>
This converts the following to Kconfig:
CONFIG_SYS_MALLOC_LEN
Signed-off-by: Tom Rini <trini@konsulko.com>
Acked-by: Sean Anderson <seanga2@gmail.com>
Reviewed-by: Rick Chen <rick@andestech.com>
- Provide a default Kconfig value of the default script
- Largely continue to define this via the board Kconfig file
- For the boards that select a script based on defconfig rather than
TARGET, keep this within the defconfig.
Signed-off-by: Tom Rini <trini@konsulko.com>
GE B1x5v2 patient monitor series is similar to the CARESCAPE Monitor
series (GE Bx50). It consists of a carrier PCB used in combination
with a Congatec QMX6 SoM. This adds U-Boot support using device model
everywhere and SPL for memory initialization.
Proper configuration is provided as 'ge_b1x5v2_defconfig' and the
combined image u-boot-with-spi.imx can be flashed directly to 1024
byte offset to /dev/mtdblock0. Alternatively SPL and u-boot.imx can
be loaded separately via USB-OTG using e.g. imx_usb.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Reviewed-by: Tom Rini <trini@konsulko.com>