unleashed-firmware/applications/external/lightmeter/lib/BH1750/BH1750.h

111 lines
2.6 KiB
C
Raw Normal View History

/**
* @file BH1750.h
* @author Oleksii Kutuzov (oleksii.kutuzov@icloud.com)
* @brief
* @version 0.1
* @date 2022-11-06
*
* @copyright Copyright (c) 2022
*
* Ported from:
* https://github.com/lamik/Light_Sensors_STM32
*/
#include <furi.h>
#include <furi_hal.h>
#ifndef BH1750_H_
#define BH1750_H_
// I2C BUS
#define I2C_BUS &furi_hal_i2c_handle_external
#define I2C_TIMEOUT 10
#define BH1750_ADDRESS (0x23 << 1)
#define BH1750_POWER_DOWN 0x00
#define BH1750_POWER_ON 0x01
#define BH1750_RESET 0x07
#define BH1750_DEFAULT_MTREG 69
#define BH1750_DEFAULT_MODE ONETIME_HIGH_RES_MODE
#define BH1750_CONVERSION_FACTOR 1.2
typedef enum { BH1750_OK = 0, BH1750_ERROR = 1 } BH1750_STATUS;
typedef enum {
CONTINUOUS_HIGH_RES_MODE = 0x10,
CONTINUOUS_HIGH_RES_MODE_2 = 0x11,
CONTINUOUS_LOW_RES_MODE = 0x13,
ONETIME_HIGH_RES_MODE = 0x20,
ONETIME_HIGH_RES_MODE_2 = 0x21,
ONETIME_LOW_RES_MODE = 0x23
} BH1750_mode;
/**
* @brief Initialize the sensor. Sends the reset command and sets the measurement register to the default value.
*
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_init();
2023-02-26 02:46:50 +00:00
/**
* @brief Change the I2C device address and then initialize the sensor.
*
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_init_with_addr(uint8_t addr);
/**
* @brief Reset all registers to the default value.
*
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_reset();
/**
* @brief Sets the power state. 1 - running; 0 - sleep, low power.
*
* @param PowerOn sensor state.
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_set_power_state(uint8_t PowerOn);
/**
* @brief Set the Measurement Time register. It allows to increase or decrease the sensitivity.
*
* @param MTreg value from 31 to 254, defaults to 69.
*
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_set_mt_reg(uint8_t MTreg);
/**
* @brief Set the mode of converting. Look into the bh1750_mode enum.
*
* @param Mode mode enumerator
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_set_mode(BH1750_mode Mode);
/**
* @brief Trigger the conversion in manual modes.
*
* @details a low-resolution mode, the conversion time is typically 16 ms, and for a high-resolution
* mode is 120 ms. You need to wait until reading the measurement value. There is no need
* to exit low-power mode for manual conversion. It makes automatically.
*
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_trigger_manual_conversion();
/**
* @brief Read the converted value and calculate the result.
*
* @param Result stores received value to this variable.
* @return BH1750_STATUS
*/
BH1750_STATUS bh1750_read_light(float* Result);
#endif /* BH1750_H_ */