In the newer versions of designware i2c IP there is the possibility
of configuring it with IC_EMPTYFIFO_HOLD_MASTER_EN=1, which basically
requires the s/w to generate the stop bit condition directly, as
the h/w will not automatically generate it when TX_FIFO is empty.
To avoid generation of an extra 0x0 byte sent as data, the
IC_STOP command must be sent along with the last IC_CMD.
This patch always writes bit[9] of ic_data_cmd even in the
older versions, assuming that it is a noop there.
Signed-off-by: Armando Visconti <armando.visconti@st.com>