// SPDX-License-Identifier: GPL-2.0+
|
|
/*
|
|
* Copyright (c) 2020, Heinrich Schuchardt <xypron.glpk@gmx.de>
|
|
*
|
|
* Test continuation of log messages.
|
|
*/
|
|
|
|
#include <common.h>
|
|
#include <console.h>
|
|
#include <test/log.h>
|
|
#include <test/test.h>
|
|
#include <test/suites.h>
|
|
#include <test/ut.h>
|
|
|
|
DECLARE_GLOBAL_DATA_PTR;
|
|
|
|
#define BUFFSIZE 64
|
|
|
|
static int log_test_cont(struct unit_test_state *uts)
|
|
{
|
|
int log_fmt;
|
|
int log_level;
|
|
|
|
log_fmt = gd->log_fmt;
|
|
log_level = gd->default_log_level;
|
|
|
|
/* Write two messages, the second continuing the first */
|
|
gd->log_fmt = (1 << LOGF_CAT) | (1 << LOGF_LEVEL) | (1 << LOGF_MSG);
|
|
gd->default_log_level = LOGL_INFO;
|
|
console_record_reset_enable();
|
|
log(LOGC_ARCH, LOGL_ERR, "ea%d ", 1);
|
|
log(LOGC_CONT, LOGL_CONT, "cc%d\n", 2);
|
|
gd->default_log_level = log_level;
|
|
gd->log_fmt = log_fmt;
|
|
gd->flags &= ~GD_FLG_RECORD;
|
|
ut_assertok(ut_check_console_line(uts, "ERR.arch, ea1 ERR.arch, cc2"));
|
|
ut_assertok(ut_check_console_end(uts));
|
|
|
|
/* Write a third message which is not a continuation */
|
|
gd->log_fmt = (1 << LOGF_CAT) | (1 << LOGF_LEVEL) | (1 << LOGF_MSG);
|
|
gd->default_log_level = LOGL_INFO;
|
|
console_record_reset_enable();
|
|
log(LOGC_EFI, LOGL_INFO, "ie%d\n", 3);
|
|
gd->default_log_level = log_level;
|
|
gd->log_fmt = log_fmt;
|
|
gd->flags &= ~GD_FLG_RECORD;
|
|
ut_assertok(ut_check_console_line(uts, "INFO.efi, ie3"));
|
|
ut_assertok(ut_check_console_end(uts));
|
|
|
|
return 0;
|
|
}
|
|