get_enable should be able to return error values. Hence change
the return type to integer.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
The RK818 PMIC contains a charger. Add very basic charger functionality
to be able to regulate the USB input current and charger shutdown limits.
Signed-off-by: Wadim Egorov <w.egorov@phytec.de>
Reviewed-by: Simon Glass <sjg@chromium.org>
Acked-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
Reviewed-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
Enabling CONFIG_SPL_POWER_SUPPORT will cause a compiler warning:
‘get_ldo_reg’ defined but not used [-Wunused-function]
Let's wrap get_ldo_reg(), rk808_ldo and rk818_ldo with ENABLE_DRIVER
which is only set for non SPL builds.
Signed-off-by: Wadim Egorov <w.egorov@phytec.de>
Reviewed-by: Simon Glass <sjg@chromium.org>
Acked-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
Reviewed-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
Till now get_ldo_reg did a return &rk808_ldo[num - 1]; to return
the ldo register offset but didn't take into account that its
calling functions already created the ldo as ldo = dev->driver_data - 1.
This resulted in the setting for ldo8 writing to the register of ldo7
and so on. So fix this and get the correct ldo register data.
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Simon Glass <sjg@chromium.org>
Since this driver can be used for rk8xx series pmic,
let's rename rk808 to rk8xx, to make it clear.
Configs parts are done by sed -i "s/RK808/RK8XX/g" `grep RK808 -lr ./`
Signed-off-by: Jacob Chen <jacob-chen@iotwrt.com>
2017-05-10 13:37:22 -06:00
Renamed from drivers/power/regulator/rk808.c (Browse further)