Add a way in configuration files (exlinux.conf for sysboot command)
to select a specific FIT configuration. The configuration is selected
with a string added after the FIT filename in the label "KERNEL" or
"LINUX", using the same format than bootm command:
KERNEL [Filename]#<conf>[#<extra-conf[#...]]
This configuration string, beginning by '#', is directly appended
to bootm argument 1 after <kernel_addr_r>.
bootm [<kernel_addr_r>]#<conf>[#<extra-conf[#...]]
see doc/uImage.FIT/command_syntax_extensions.txt for details
Example :
KERNEL /fit.itb#cfg1
KERNEL /fit.itb#cfg2
Configuration can be use also for overlay management :
KERNEL /fit.itb#cfg1#dtbo1#dtbo3
see doc/uImage.FIT/overlay-fdt-boot.txt for details
Signed-off-by: Patrick Delaunay <patrick.delaunay@st.com>
When U-Boot started using SPDX tags we were among the early adopters and
there weren't a lot of other examples to borrow from. So we picked the
area of the file that usually had a full license text and replaced it
with an appropriate SPDX-License-Identifier: entry. Since then, the
Linux Kernel has adopted SPDX tags and they place it as the very first
line in a file (except where shebangs are used, then it's second line)
and with slightly different comment styles than us.
In part due to community overlap, in part due to better tag visibility
and in part for other minor reasons, switch over to that style.
This commit changes all instances where we have a single declared
license in the tag as both the before and after are identical in tag
contents. There's also a few places where I found we did not have a tag
and have introduced one.
Signed-off-by: Tom Rini <trini@konsulko.com>
Use environment variable "kernel_addr_r" to indicate the location
in RAM where FIT image will be stored.
Use label command "kernel" to indicate which <path> the FIT image at.
Signed-off-by: Wenbin Song <wenbin.song@nxp.com>
Correct spelling of "U-Boot" shall be used in all written text
(documentation, comments in source files etc.).
Signed-off-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Heiko Schocher <hs@denx.de>
Reviewed-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Minkyu Kang <mk7.kang@samsung.com>
Now DT support is becoming common for all new SoC's. Hence it is better
to have option for getting specific FDT from the remote server.
This patch adds support for new label i.e. 'fdt'. This will allow to
retrieve 'fdt blob' from the remote server. This patch take care for
the following scenarios.
The usage of fdt is optional.
The 'fdt blob' can be retrieved from tftp or can be available locally
or can be absent.
If 'fdt_addr_r' environment variable is set and 'fdt' label is defined
retrieve 'fdt blob' from tftp. 'fdt_addr_r' is then passed along bootm
command.
If 'fdt_addr' is set and 'fdt blob' is not retrieved from the tftp pass
'fdt_addr' to bootm command. In this case 'fdt blob' will be available
at 'fdt_addr'.
If 'fdt_addr' is not set and 'fdt blob' is not retrieve from tftp pass
NULL to boot command. In this case 'fdt blob' is not required and absent.
Signed-off-by: Chander Kashyap <chander.kashyap@linaro.org>
Acked-by: Jason Hobbs <jason.hobbs@calxeda.com>
For syslinux, the initrd can be set in the append string as
"initrd=<file>", so try to find it there if we haven't already set the
initrd.
Signed-off-by: Rob Herring <rob.herring@calxeda.com>
Fix trailing white space, indentation by spaces instead of TABs,
excessive blank lines, trailing blank lines.
Signed-off-by: Wolfgang Denk <wd@denx.de>
Add pxe command, which is intended to mimic PXELINUX functionality.
'pxe get' uses tftp to retrieve a file based on UUID, MAC address or IP
address. 'pxe boot' interprets the contents of PXELINUX config like file
to boot using a specific initrd, kernel and kernel command line.
This patch also adds a README.pxe file - see it for more details on the
pxe command.
Signed-off-by: Jason Hobbs <jason.hobbs@calxeda.com>