Commit graph

3 commits

Author SHA1 Message Date
Mario Six
c550389881 cmd: mdio: Fix style violations
Fix some style violations in the MDIO command.

Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Signed-off-by: Mario Six <mario.six@gdsys.cc>
2018-02-26 15:47:43 -06:00
Michal Simek
15a2acdf85 common: miiphyutil: Work and report phy address in hex in mdio cmd
It is confusing that mdio commands work and report phy id as
decimal value when mii is working with hex values.

For example:
ZynqMP> mdio list
gem:
21 - TI DP83867 <--> ethernet@ff0e0000
ZynqMP> mdio read ethernet@ff0e0000 0
Reading from bus gem
PHY at address 21:
0 - 0x1140
ZynqMP> mii dump 21 0
Incorrect PHY address. Range should be 0-31
...
ZynqMP> mii dump 15
0.     (1140)                 -- PHY control register --
  (8000:0000) 0.15    =     0    reset

U-Boot normally takes hex values that's why this patch is changing mdio
command to handle hex instead of changing mii command to handle decimal
values.

Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
2016-12-02 14:36:02 +01:00
Simon Glass
2e192b245e Remove the cmd_ prefix from command files
Now that they are in their own directory, we can remove this prefix.
This makes it easier to find a file since the prefix does not get in the
way.

Signed-off-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Heiko Schocher <hs@denx.de>
Acked-by: Stefan Roese <sr@denx.de>
Acked-by: Przemyslaw Marczak <p.marczak@samsung.com>
2016-01-25 10:39:43 -05:00
Renamed from cmd/cmd_mdio.c (Browse further)