At present various drivers etc. access the device's 'seq' member directly.
This makes it harder to change the meaning of that member. Change access
to go through a function instead.
The drivers/i2c/lpc32xx_i2c.c file is left unchanged for now.
Signed-off-by: Simon Glass <sjg@chromium.org>
This name is far too long. Rename it to remove the 'data' bits. This makes
it consistent with the platdata->plat rename.
Signed-off-by: Simon Glass <sjg@chromium.org>
We use 'priv' for private data but often use 'platdata' for platform data.
We can't really use 'pdata' since that is ambiguous (it could mean private
or platform data).
Rename some of the latter variables to end with 'plat' for consistency.
Signed-off-by: Simon Glass <sjg@chromium.org>
This construct is quite long-winded. In earlier days it made some sense
since auto-allocation was a strange concept. But with driver model now
used pretty universally, we can shorten this to 'auto'. This reduces
verbosity and makes it easier to read.
Coincidentally it also ensures that every declaration is on one line,
thus making dtoc's job easier.
Signed-off-by: Simon Glass <sjg@chromium.org>
flush_cache() arguments are not type casted to take care of 64 bit
systems. Use phys_addr_t to type cast for it to work properly for 32 bit
and 64 bit systems.
Signed-off-by: Ashok Reddy Soma <ashok.reddy.soma@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Reviewed-by: Ramon Fried <rfried.dev@gmail.com>
There are compilation warnings showing up when we compile AXI ethernet
driver for 64bit architectures. Fix them, so that it works on both 32
and 64 bit architectures.
DMA descriptors are not taking care of 64bit addresses. To fix it,
change axidma_bd members as below:
next ==> next_desc
reserverd1 ==> next_desc_msb
phys ==> buf_addr
reserverd2 ==> buf_addr_msb
and update next_desc and buf_addr with lower 32 bits of the addresses,
update next_desc_msb and buf_addr_msb with upper 32 bits of the 64bit
addresses.
Signed-off-by: Ashok Reddy Soma <ashok.reddy.soma@xilinx.com>
Reviewed-by: Ramon Fried <rfried.dev@gmail.com>
When you enable CONFIG_OF_LIVE, you will end up with a lot of
conversions.
To generate this commit, I used coccinelle excluding drivers/core/,
include/dm/, and test/
The semantic patch that makes this change is as follows:
<smpl>
@@
expression dev;
@@
-devfdt_get_addr(dev)
+dev_read_addr(dev)
</smpl>
Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
When you enable CONFIG_OF_LIVE, you will end up with a lot of
conversions.
To generate this commit, I used coccinelle excluding drivers/core/,
include/dm/, and test/
The semantic patch that makes this change is as follows:
<smpl>
@@
expression dev;
@@
-devfdt_get_addr(dev)
+dev_read_addr(dev)
</smpl>
Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
The index used to iterate over the possible PHYs in axiemac_phy_init was an
unsigned int and decremented. Therefor it was always >= 0 and never exited
the loop.
Signed-off-by: Patrick van Gelder <patrick.vangelder@nl.bosch.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
These functions are CPU-related and do not use driver model. Move them to
cpu_func.h
Signed-off-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Daniel Schwierzeck <daniel.schwierzeck@gmail.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
This patch assings the phynode pointer to the phydev node as it is needed
later in the corresponding phy driver to read phy properties from DT.
Signed-off-by: Siva Durga Prasad Paladugu <siva.durga.paladugu@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
When U-Boot started using SPDX tags we were among the early adopters and
there weren't a lot of other examples to borrow from. So we picked the
area of the file that usually had a full license text and replaced it
with an appropriate SPDX-License-Identifier: entry. Since then, the
Linux Kernel has adopted SPDX tags and they place it as the very first
line in a file (except where shebangs are used, then it's second line)
and with slightly different comment styles than us.
In part due to community overlap, in part due to better tag visibility
and in part for other minor reasons, switch over to that style.
This commit changes all instances where we have a single declared
license in the tag as both the before and after are identical in tag
contents. There's also a few places where I found we did not have a tag
and have introduced one.
Signed-off-by: Tom Rini <trini@konsulko.com>
This patch uses writeq() function to enable greater than 32 bit
addressing of axi-ethernet for the ZynqMP devices.
Signed-off-by: Vipul Kumar <vipulk@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
wait_for_bit callers use the 32 bit LE version
Signed-off-by: Álvaro Fernández Rojas <noltari@gmail.com>
Reviewed-by: Daniel Schwierzeck <daniel.schwierzeck@gmail.com>
Reviewed-by: Jagan Teki <jagan@openedev.com>
This patch uses readl and writel instead of in_be32 and
out_be32 for io ops as these internally uses readl,
writel for microblaze and for Zynq, ZynqMP there is
no need of endianness conversion and readl, writel
should work straightaway. This patch starts supporting
the driver for Zynq and ZynqMP platforms.
Signed-off-by: Siva Durga Prasad Paladugu <sivadur@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Add support for non processor mode, this mode doesn't have
access to some of the registers and hence this patch
bypasses it and also length has to be calculated from
status instead of app4 in this mode.
Signed-off-by: Siva Durga Prasad Paladugu <sivadur@xilinx.com>
Read dma address using fdtdec_get_addr as it checks for
address cells and size cells and reads the address
properly. fdtdec_get_int always assume address is of int
size which goes wrong if using it on 64-bit architecture.
Signed-off-by: Siva Durga Prasad Paladugu <sivadur@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
These support the flat device tree. We want to use the dev_read_..()
prefix for functions that support both flat tree and live tree. So rename
the existing functions to avoid confusion.
In the end we will have:
1. dev_read_addr...() - works on devices, supports flat/live tree
2. devfdt_get_addr...() - current functions, flat tree only
3. of_get_address() etc. - new functions, live tree only
All drivers will be written to use 1. That function will in turn call
either 2 or 3 depending on whether the flat or live tree is in use.
Note this involves changing some dead code - the imx_lpi2c.c file.
Signed-off-by: Simon Glass <sjg@chromium.org>
At present devices use a simple integer offset to record the device tree
node associated with the device. In preparation for supporting a live
device tree, which uses a node pointer instead, refactor existing code to
access this field through an inline function.
Signed-off-by: Simon Glass <sjg@chromium.org>
axi_emac, emaclite and gem have the same issue with registering
multiple instances with mdio busses. mdio bus name has to be uniq but
drivers are setting up only one name for all.
Use mdio_register_seq() and pass dev->seq number to allow multiple
mdio instances registration.
Reported-by: Phani Kiran Kara <phanikiran.kara@gmail.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
axi_emac, emaclite and gem have the same issue with registering
multiple instances with mdio busses. mdio bus name has to be uniq but
drivers are setting up only one name for all.
Use mdio_register_seq() and pass dev->seq number to allow multiple
mdio instances registration.
Reported-by: Phani Kiran Kara <phanikiran.kara@gmail.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Series-to: u-boot
Series-cc: Phani Kiran Kara <phanikiran.kara@gmail.com>
In SGMII cases the isolate bit might set after DMA and
ethernet resets and hence check and clear during
setup_phy if it was set.
Signed-off-by: Siva Durga Prasad Paladugu <sivadur@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Pass appropriate interface type to phy_connect
instead of zero.
Signed-off-by: Siva Durga Prasad Paladugu <sivadur@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Also add dependency on PHYLIB and MII which is required.
Clean PHYLIB dependency from the driver too.
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Rename few functions to fit to the new name convention used by DM.
Suggested-by: Joe Hershberger <joe.hershberger@ni.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Saving iobase directly to private structure helps with moving to DM.
There is an option to load iobase from pdata but it is additional load.
Pointer to private structure is available all the time.
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Simplify mdio_wait function by passing regs directly.
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Fix these compilation warning by proper grouping:
In function 'axi_dma_init': drivers/net/xilinx_axi_emac.c:391:7:
warning: suggest parentheses around operand of '!' or change '&' to '&&'
or '!' to '~' [-Wparentheses]
if (!(in_be32(&priv->dmatx->control) |
^
In function 'axiemac_send': drivers/net/xilinx_axi_emac.c:501:21:
warning: suggest parentheses around operand of '!' or change '&' to '&&'
or '!' to '~' [-Wparentheses]
while (timeout && (!in_be32(&priv->dmatx->status) &
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Update the naming convention used in the network stack functions and
variables that Ethernet drivers use to interact with it.
This cleans up the temporary hacks that were added to this interface
along with the DM support.
This patch has a few remaining checkpatch.pl failures that would be out
of the scope of this patch to fix (drivers that are in gross violation
of checkpatch.pl).
Signed-off-by: Joe Hershberger <joe.hershberger@ni.com>
Acked-by: Simon Glass <sjg@chromium.org>
As tsec and fm drivers checking phydev->link
ensure that u-boot don't try access device if link is not ready.
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Now that phy_startup() can return an actual error code, check for that error
code and abort network initialization if the PHY fails.
Signed-off-by: Timur Tabi <timur@freescale.com>
Acked-by: Nobuhiro Iwamamatsu <nobuhiro.iwamatsu.yj@renesas.com> (sh_eth part)
Acked-by: Stephan Linz <linz@li-pro.net> (Xilinx part, xilinx_axi_emac and xilinx_ll_temac)
Reviewed-by: Marek Vasut <marex@denx.de> (FEC part)
Fix this:
xilinx_axi_emac.c: In function 'xilinx_axiemac_initialize':
xilinx_axi_emac.c:646: warning: assignment from incompatible pointer type
Signed-off-by: Stephan Linz <linz@li-pro.net>
Add axi_ethernet driver for little-endian Microblaze.
RX/TX BDs and rxframe buffer are shared among all axi_ethernet MACs.
Only one MAC can work in one time.
Signed-off-by: Michal Simek <monstr@monstr.eu>
Acked-by: Mike Frysinger <vapier@gentoo.org>