MXS SSP controller may have up to three chip selects per port: SS0, SS1 and SS2.
Currently only SS0 is supported in the mxs_spi driver.
Allow all the three chip select to work by selecting the desired one
in bits 20 and 21 of the HW_SSP_CTRL0 register.
Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
Acked-by: Marek Vasut <marex@denx.de>
Introduce spi_cs_is_valid() for validating spi bus and chip select numbers.
Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
Acked-by: Marek Vasut <marex@denx.de>
Acked-by: Mike Frysinger <vapier@gentoo.org>
Instead of returning -1, it is preferred to return -ETIMEDOUT in case of timeouts.
Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
Acked-by: Marek Vasut <marex@denx.de>
The generic spi flash driver (drivers/mtd/spi/spi_flash.c) uses the
spi low level driver's spi_xfer() function with len=0 to deassert the
SPI flash' chip select. But the i.MX28 spi driver rejects this call
due to len=0.
This patch implements an exception for len=0 with the SPI_XFER_END
flag set. This results in an extra read with the chip select being
deasserted afterwards. There seems to be no way to deassert the signal
by hand.
Signed-off-by: Matthias Fuchs <matthias.fuchs@esd.eu>
Tested-by: Fabio Estevam <fabio.estevam@freescale.com>