Commit graph

4 commits

Author SHA1 Message Date
Michal Simek
6ecbb45bb0 hwmon: Cleaning hwmon devices
Clean Makefile
Move device specific values to driver for better reading

Signed-off-by: Michal Simek <monstr@monstr.eu>
Acked-by: Stefan Roese <sr@denx.de>
2008-07-13 15:26:18 +02:00
Stefan Roese
4d91d1df2f DTT: Issue one-shot command on AD7414 (LM75 code) to read temp
On AD7414 the first value upon bootup is not read correctly.
This is most likely because of the 800ms update time of the
temp register in normal update mode. To get current values
each time we issue the "dtt" command including upon powerup
we switch into one-short mode.

This patch fixes the problem on AD7414 equipped boards (Sequoia,
Canyonlands etc), that temp value printed in the bootup log was
incorrect.

Signed-off-by: Stefan Roese <sr@denx.de>
2008-06-03 21:00:00 +02:00
Larry Johnson
d01b847c5c LM75 bug fix for negative temperatures
When the LM75 temperature sensor measures a temperature below 0 C, the
current driver does not perform sign extension, so the result returned is
256 C too high.  This patch fixes the problem.

Signed-off-by: Larry Johnson <lrj@acm.org>
2008-02-22 16:33:09 +01:00
Jean-Christophe PLAGNIOL-VILLARD
f868cc5a50 drivers/hwmon : move hardware monitor drviers to drivers/hwmon
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
2007-11-25 23:28:50 +01:00
Renamed from dtt/lm75.c (Browse further)