Migrate the BR/OR settings to Kconfig. These must be known at compile
time, so cannot be configured via DT.
Configuration of this crucial variable should still be somewhat
comfortable. Hence, make its fields configurable in Kconfig, and
assemble the final value from these.
Signed-off-by: Mario Six <mario.six@gdsys.cc>
Re-format all BR,OR #define lines into single lines. This makes them
harder to read, but accessible to semi-automatic replacement.
Signed-off-by: Mario Six <mario.six@gdsys.cc>
All BR/OR option lines should have the same layout to make them easier
to migrate to Kconfig. This includes using the same option macros
everywhere.
The normalize the lines,
* replace function macros with their results, and
* replace hardcoded hex values with standard macros
Signed-off-by: Mario Six <mario.six@gdsys.cc>
The LBLAW_* values determine the window configuration of the memory
controller. Hence, they must be known at compile time, and cannot be
implemented in the DT mechanism.
Configuration of this crucial variable should still be somewhat
comfortable. Hence, make its fields configurable in Kconfig, and
assemble the final value from these.
Signed-off-by: Mario Six <mario.six@gdsys.cc>
The BATs (block address translation registers) determine the initial
memory window mappings. Hence, they must be known at compile time and
cannot be implemented in the DT mechanism.
Configuration of this crucial variable should still be somewhat
comfortable. Hence, make its fields configurable in Kconfig, and
assemble the final value from these.
Signed-off-by: Mario Six <mario.six@gdsys.cc>
The HRCW (hardware reset configuration word) is a constant that must be
hard-coded into the boot loader image. So, it must be available at
compile time, and cannot be migrated to the DT mechanism, but has to be
kept in Kconfig.
Configuration of this crucial variable should still be somewhat
comfortable. Hence, make its fields configurable in Kconfig, and
assemble the final value from these.
Signed-off-by: Mario Six <mario.six@gdsys.cc>
MPC83xx uses CONFIG_83XX_CLKIN instead of CONFIG_SYS_CLK_FREQ to set the
system clock. To migrate the architecture, we can replace
CONFIG_83XX_CLKIN with CONFIG_SYS_CLK_FREQ.
To do this
* replace all occurrences of CONFIG_83XX_CLKIN with CONFIG_SYS_CLK_FREQ
* set CONFIG_SYS_CLK_FREQ to the old value of CONFIG_83XX_CLKIN in all
MPC83xx config files
Signed-off-by: Mario Six <mario.six@gdsys.cc>
CONFIG_MPC8313ERDB is unused, and
TARGET_MPC8313ERDB_NAND/TARGET_MPC8313ERDB_NOR Kconfig could replace it.
Hence, get rid of CONFIG_MPC8313ERDB.
Signed-off-by: Mario Six <mario.six@gdsys.cc>
MPC8313ERDB has the option of either enabling NOR or NAND boot in its
config file (by commenting out certain #ifdefs). To keep this ability
after migrating options to Kconfig, we introduce two MPC8313ERDB
configs: one for NOR, and one for NAND.
Signed-off-by: Mario Six <mario.six@gdsys.cc>