Current xilinx_timer_get_count() implementation does not take into account
the periodic 32-bit wrap arounds, as it directly returns the 32-bit counter
register value. The roll-overs cause problems in the upper timer layers, as
generic timer code expects an incrementing 64-bit value from get_count() to
work correctly.
Add the missing 64-bit up-conversion to fix random hangs/delays in
__udelay().
Fixes: a36d86720f ("microblaze: Convert axi timer to DM driver")
Signed-off-by: Ovidiu Panait <ovpanait@gmail.com>
Reviewed-by: Michal Simek <michal.simek@amd.com>
Link: https://lore.kernel.org/r/20221012053656.1492457-3-ovpanait@gmail.com
Signed-off-by: Michal Simek <michal.simek@amd.com>
Move axi timer driver from Microblaze to generic location.
Origin implementation was irq based with counting down timer.
CONFIG_TIMER drivers are designed differently that timer is free running up
timer with automatic reload without any interrupt.
Information about clock rates are find out in timer_pre_probe() that's why
there is no need to get any additional information from DT in the driver
itself (only register offset).
Signed-off-by: Michal Simek <michal.simek@amd.com>
Tested-by: Ovidiu Panait <ovidiu.panait@windriver.com>
Link: https://lore.kernel.org/r/6c12fc86bbc1f17d05c25018862e7b7b03346b36.1654684731.git.michal.simek@amd.com