The K3 SoCs have some PLL output clocks (POSTDIV clocks) which in
turn serve as inputs to other HSDIV output clocks. These clocks use
the actual value to compute the divider clock rate, and need to be
registered with the CLK_DIVIDER_ONE_BASED flags. The current k3-clk
driver and data lacks the infrastructure to pass in divider flags.
Update the driver and data to account for these divider flags.
Signed-off-by: Suman Anna <s-anna@ti.com>
Signed-off-by: Dave Gerlach <d-gerlach@ti.com>
Add a note to the automatically generated clk-data and dev-data files
for j721e and j7200 to indicate that they are in fact auto-generated and
should not be hand edited.
Also adjust TI URL to use https instead of http and also add an empty
line before first header inclusion.
Signed-off-by: Dave Gerlach <d-gerlach@ti.com>
The TI K3 Fractional PLLs use two programmable POSTDIV1 and POSTDIV2
divisors to generate the final FOUTPOSTDIV clock. These are in sequence
with POSTDIV2 following the POSTDIV1 clock. The current J721E clock data
has the POSTDIV2 clock as the parent for the POSTDIV1 clock, which is
opposite of the actual implementation. Fix the data by simply adjusting
the register bit-shifts.
The Main PLL1 POSTDIV clocks were also defined incorrectly using Main PLL0
register values, fix these as well.
Fixes: 277729eaf3 ("arm: mach-k3: Add platform data for j721e and j7200")
Signed-off-by: Suman Anna <s-anna@ti.com>
Signed-off-by: Dave Gerlach <d-gerlach@ti.com>
Add platform clock and powerdomain data for J721e and J7200. This data
is used by the corresponding drivers to register all the required device
clocks and powerdomains.
Signed-off-by: Dave Gerlach <d-gerlach@ti.com>
Signed-off-by: Tero Kristo <kristo@kernel.org>