This patch corrects the divider value written to CLKDIV register.
Since SDCLKIN is divided inside controller by the DIVRATIO value set
in the CLKSEL register, we need to use the same output clock value to
calculate the CLKDIV value.
as per user manual: cclk_in = SDCLKIN / (DIVRATIO + 1)
Input parameter to mmc_clk is changed to dwmci_host, since
we need the same to read DWMCI_CLKSEL register.
This improves the read timing values for channel 0 on SMDK5250
from 0.288sec to 0.144sec
Signed-off-by: Rajeshwari S Shinde <rajeshwari.s@samsung.com>
Acked-by: Jaehoon Chung <jh80.chung@samsung.com>
Signed-off-by: Pantelis Antoniou <panto@antoniou-consulting.com>
SMDK5420 has a new Security Management Unit added
for dwmmc driver, hence, configuring the control
registers to support booting via eMMC.
Signed-off-by: Alim Akhtar <alim.akhtar@samsung.com>
Signed-off-by: Rajeshwari Shinde <rajeshwari.s@samsung.com>
Acked-by: Simon Glass <sjg@chromium.org>
Acked-by: Jaehoon Chung <jh80.chung@samsung.com>
Acked-by: Pantelis Antoniou <panto@antoniou-consulting.com>
This patch adds FDT support for DWMMC, by reading the DWMMC node data
from the device tree and initialising DWMMC channels as per data
obtained from the node.
Signed-off-by: Vivek Gautam <gautam.vivek@samsung.com>
Signed-off-by: Amar <amarendra.xt@samsung.com>
Acked-by: Simon Glass <sjg@chromium.org>
Signed-off-by: Minkyu Kang <mk7.kang@samsung.com>