Commit graph

10 commits

Author SHA1 Message Date
Marek Vasut
f282e32d0a net: phy: ksz8xxx: Convert to U_BOOT_PHY_DRIVER()
Convert PHY driver to U_BOOT_PHY_DRIVER() macro and drop phy_register() init call.

Converted using sed
"s@^static struct phy_driver \(.*\)_driver = \+{@U_BOOT_PHY_DRIVER(\L\1) = {"

Signed-off-by: Marek Vasut <marek.vasut+renesas@mailbox.org>
Acked-by: Michal Simek <michal.simek@amd.com>
Tested-by: Michal Simek <michal.simek@amd.com> #microblaze (MANUAL_RELOC)
2023-04-07 14:18:49 +02:00
Bryan O'Donoghue
baafd99d13 net: phy: micrel: ksz8061 implement errata 80000688A fix
Linux commit 232ba3a51cc2 ('net: phy: Micrel KSZ8061: link failure after
cable connect') implements a fix for the above errata.

This patch replicates that errata fix in an ksz8061 specific init routine.

Signed-off-by: Bryan O'Donoghue <bod@denx.de>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
2020-06-12 13:17:23 -04:00
Simon Glass
cd93d625fd common: Drop linux/bitops.h from common header
Move this uncommon header out of the common header.

Signed-off-by: Simon Glass <sjg@chromium.org>
2020-05-18 21:19:23 -04:00
Nicolas Ferre
b2f2643b39 net: phy: micrel: make sure the factory test bit is cleared
The KSZ8081 PHY has a factory test mode which is set at the de-assertion
of the reset line based on the RXER (KSZ8081RNA/RND) or TXC
(KSZ8081MNX/RNB) pin. If a pull-down is missing, or if the pin has a
pull-up, the factory test mode should be cleared by manually writing a 0
(according to the datasheet).
Create another ksz8081_config function to handle this case.

Suggested-by: Antoine Tenart <antoine.tenart@bootlin.com>
Signed-off-by: Nicolas Ferre <nicolas.ferre@microchip.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
2019-12-09 09:47:42 -06:00
James Byrne
77b508d34b net: phy: micrel: Allow KSZ8xxx and KSZ90x1 to be used together
Commit d397f7c45b ("net: phy: micrel: Separate KSZ9000 drivers from
KSZ8000 drivers") separated the KSZ8xxx and KSZ90x1 drivers and warns
that you shouldn't select both of them due to a device ID clash between
the KSZ9021 and the KS8721, asserting that "it is highly unlikely for a
system to contain both a KSZ8000 and a KSZ9000 PHY". Unfortunately
boards like the SAMA5D3xEK do contain both types of PHY, but fortunately
the Linux Micrel PHY driver provides a solution by using different PHY
ID and mask values to distinguish these chips.

This commit contains the following changes:

- The PHY ID and mask values for the KSZ9021 and the KS8721 now match
those used by the Linux driver.
- The warnings about not enabling both drivers have been removed.
- The description for PHY_MICREL_KSZ8XXX has been corrected (these are
10/100 PHYs, not GbE PHYs).
- PHY_MICREL_KSZ9021 and PHY_MICREL_KSZ9031 no longer select PHY_GIGE
since this is selected by PHY_MICREL_KSZ90X1.
- All of the relevant defconfig files have been updated now that
PHY_MICREL_KSZ8XXX does not default to 'Y'.

Signed-off-by: James Byrne <james.byrne@origamienergy.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
2019-05-14 14:43:33 -05:00
Joe Hershberger
05b60ac549 net: phy: Clean up includes of common.h
We want to be able to include some other system headers in phy.h but
that requires us to have included common.h in the top-level first.

Also, common.h includes config.h as the first thing it does, so don't
include it directly.

Series-to: u-boot
Series-cc: Grygorii Strashko <grygorii.strashko@ti.com>
Seried-cc: ti
Series-process-log: sort, uniq
Cover-letter:
Prepare for net: phy: prevent uclass_eth device "node" field overwriting
Prepare for [1] so that it doesn't break the build for a bunch of
boards. There are a number of reasons this series broke the build
but none of them depend on changes in the series, so fix up those
situations ahead of applying that series.

[1] https://patchwork.ozlabs.org/cover/940104/
END
Signed-off-by: Joe Hershberger <joe.hershberger@ni.com>
2018-07-26 14:08:22 -05:00
Tom Rini
83d290c56f SPDX: Convert all of our single license tags to Linux Kernel style
When U-Boot started using SPDX tags we were among the early adopters and
there weren't a lot of other examples to borrow from.  So we picked the
area of the file that usually had a full license text and replaced it
with an appropriate SPDX-License-Identifier: entry.  Since then, the
Linux Kernel has adopted SPDX tags and they place it as the very first
line in a file (except where shebangs are used, then it's second line)
and with slightly different comment styles than us.

In part due to community overlap, in part due to better tag visibility
and in part for other minor reasons, switch over to that style.

This commit changes all instances where we have a single declared
license in the tag as both the before and after are identical in tag
contents.  There's also a few places where I found we did not have a tag
and have introduced one.

Signed-off-by: Tom Rini <trini@konsulko.com>
2018-05-07 09:34:12 -04:00
Tom Rini
d024236e5a Remove unnecessary instances of DECLARE_GLOBAL_DATA_PTR
We have a large number of places where while we historically referenced
gd in the code we no longer do, as well as cases where the code added
that line "just in case" during development and never dropped it.

Signed-off-by: Tom Rini <trini@konsulko.com>
2018-04-27 14:54:48 -04:00
Alexandru Gagniuc
fbc120e668 net: phy: micrel: Remove ksz90x1 drivers from micrel_ksz8xxx
There should be no longer be any ksz9000 users that pick up the PHY
driver from ksz8xxx, so remove ksz9000 remnants from there.

Signed-off-by: Alexandru Gagniuc <alex.g@adaptrum.com>
Reviewed-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
2017-08-07 15:18:30 -05:00
Alexandru Gagniuc
d397f7c45b net: phy: micrel: Separate KSZ9000 drivers from KSZ8000 drivers
The KS8721BL and KSZ9021 PHYs are software-incompatible, yet they
share the same ID. Drivers for bothe PHYs cannot safely coexist, so
the solution was to use #ifdefs to select between the two drivers.

As a result KSZ9031, which has a unique ID, is now caught in the
crossfire. Unless CONFIG_PHY_MICREL_KSZ9031 is defined, the KSZ9031
will not function properly, as some essential configuration code is
ifdef'd-out.

To prevent such situations, move the KSZ9000 drivers to a separate
file, and place them under a separate Kconfig option. While it is
possible to enable both KSZ8000 and KSZ9000 drivers at the same time,
the assumption is that it is highly unlikely for a system to contain
both a KSZ8000 and a KSZ9000 PHY, and that only one of the drivers
will be enabled at any given time.

Signed-off-by: Alexandru Gagniuc <alex.g@adaptrum.com>
Reviewed-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
2017-08-07 15:18:30 -05:00
Renamed from drivers/net/phy/micrel.c (Browse further)