This converts the PLMT driver from the riscv-specific timer interface to be
a DM-based UCLASS_TIMER driver.
The clock-frequency/clocks properties are preferred over timebase-frequency
for two reasons. First, properties which affect a device should be located
near its binding in the device tree. Using timebase-frequency only really
makes sense when the cpu itself is the timer device. This is the case when
we read the time from a CSR, but not when there is a separate device.
Second, it lets the device use the clock subsystem which adds flexibility.
If the device is configured for a different clock speed, the timer can
adjust itself.
Signed-off-by: Sean Anderson <seanga2@gmail.com>
Reviewed-by: Rick Chen <rick@andestech.com>
The platform-Level Machine Timer (PLMT) block
holds memory-mapped mtime register associated
with timer tick.
This driver implements the riscv_get_time() which
is required by the generic RISC-V timer driver.
Signed-off-by: Rick Chen <rick@andestech.com>
Cc: Greentime Hu <greentime@andestech.com>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Lukas Auer <lukas.auer@aisec.fraunhofer.de>
The Platform-Level Interrupt Controller (PLIC)
block holds memory-mapped claim and pending registers
associated with software interrupt. It is required
for handling IPI.
Signed-off-by: Rick Chen <rick@andestech.com>
Cc: Greentime Hu <greentime@andestech.com>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Lukas Auer <lukas.auer@aisec.fraunhofer.de>
This adds U-Boot syscon driver for SiFive's Core Local Interruptor
(CLINT). The CLINT block holds memory-mapped control and status
registers associated with software and timer interrupts.
This driver implements the riscv_get_time() API as required by
the generic RISC-V timer driver, as well as some other APIs that
are needed for handling IPI.
Signed-off-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Lukas Auer <lukas.auer@aisec.fraunhofer.de>
Reviewed-by: Anup Patel <anup@brainfault.org>