Now that a regulator driver exists for this PMIC, hook it up to the
device tree "regulators" subnodes.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Subordinate regulator drivers can use this enumerated ID instead of
matching the compatible string again.
Reviewed-by: Andre Przywara <andre.przywara@arm.com>
Signed-off-by: Samuel Holland <samuel@sholland.org>
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
The AXP PMICs have the ability to power off the system. The existing
code for this is duplicated for each PMIC variant, and uses the legacy
non-DM "pmic_bus" interface. When SYSRESET is enabled, this can all be
replaced with a sysreset device using the DM_PMIC interface.
Since the trigger bit is the same on all PMIC variants, use the register
definitions from the oldest supported PMIC.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Andre Przywara <andre.przywara@arm.com>
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
These PMICs provide some combination of battery charger, fuel gauge,
GPIOs, regulators, and VBUS routing. These functions are represented
as child nodes in the device tree. Add the minimal driver needed to
probe these child devices and provide the DM_PMIC ops.
Enable the driver by default for SoCs that normally pair with a PMIC.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Andre Przywara <andre.przywara@arm.com>
Signed-off-by: Andre Przywara <andre.przywara@arm.com>