Receive FIFO level register is different in SH4A.
Because register is different, cannot occasionally receive data.
Signed-off-by: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
SH7780 is CPU of Renesas Technology.
This CPU has
- CPU clock 400MHz
- PCI support
- DDR-SDRAM controller
- etc ...
Signed-off-by: Yusuke Goda <goda.yusuke@renesas.com>
Signed-off-by: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
This patch fixed wrong SH7720 CPU macro and changed macro that
calculated value of SCBRR register.
Signed-off-by: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
SH7710/SH7712 of SH3 CPU are supported.
SH771X is called SH-Ether, and has the Ether controller in CPU.
The driver of Ether is not included in this patch.
Signed-off-by: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
The composition of the directory in the drivers/ changed.
I moved SuperH serial driver and marubun PCMCIA driver.
Signed-off-by: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>