Add do_disable_clocks() to disable clock domains and module clocks.
These clocks are enabled using do_enable_clocks().
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Vignesh R <vigneshr@ti.com>
Reviewed-by: Jagan Teki <jteki@openedev.com>
Similar to OMAP4/5 we need to scale the voltage up prior to changing the
clock frequencies up higher. Add a similar hook to start with.
Signed-off-by: Tom Rini <trini@ti.com>
Updating the Multiplier and Dividers value for all DPLLs.
Safest OPP is read from DEV ATTRIBUTE register. Accoring to the value
returned the MPU DPLL is locked.
At different OPPs follwoing are the MPU locked frequencies.
OPP50 300MHz
OPP100 600MHz
OPP120 720MHz
OPPTB 800MHz
OPPNT 1000MHz
According to the latest DM following is the OPP table dependencies:
VDD_CORE VDD_MPU
OPP50 OPP50
OPP50 OPP100
OPP100 OPP50
OPP100 OPP100
OPP100 OPP120
So at different OPPs of MPU it is safest to lock CORE at OPP_NOM.
Following are the DPLL locking frequencies at OPP NOM:
Core locks at 1000MHz
Per locks at 960MHz
LPDDR2 locks at 266MHz
DDR3 locks at 400MHz
Touching AM33xx files also to get DPLL values specific to board but no
functionality difference.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Signed-off-by: Antoine Tenart <atenart@adeneo-embedded.com>
[trini: Fix warnings about vtp things in emif4.c, adapt AM43XX]
Signed-off-by: Tom Rini <trini@ti.com>
Cleaning up the clocks layer.
This helps in addition of new Soc with minimal
changes.
This is derived from OMAP4 boards.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Tested-by: Heiko Schocher <hs@denx.de>
Acked-by: Heiko Schocher <hs@denx.de>
Locking sequence for all the dplls is same.
In the current code same sequence is done repeatedly
for each dpll. Instead have a generic function
for locking dplls and pass dpll data to that function.
This is derived from OMAP4 boards.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Tested-by: Heiko Schocher <hs@denx.de>
Acked-by: Heiko Schocher <hs@denx.de>