Add support to specify the Ethernet buffer base address;
if none are supply by the board, the default value is use (from existing code).
Signed-off-by: Sylvain Lemieux <slemieux@tycoint.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
LPC32xx MAC and clock control configuration requires some minor quirks
to deal with a phy connected by RMII.
It's worth to mention that the kernel and legacy BSP from NXP sets
SUPP_RESET_RMII == (1 << 11) bit, however the description of this bit is
missing in shared LPC32x0 User Manual UM10326 Rev. 3, July 22, 2011
and in LPC32x0 Draft User Mannual Rev. 00.27, November 20, 2008, also
in my tests an SMSC LAN8700 phy device connected over RMII seems to
work correctly without touching this bit.
Add support of RMII, if CONFIG_RMII is defined, this option is aligned
with a number of boards, which already define the same config value.
Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Tested-by: Sylvain Lemieux <slemieux@tycoint.com>
This change rearranges general MAC configuration and PHY specific
configuration of MAC registers (duplex mode and speed), before this
change set bits related to PHY configuration in MAC2 and COMMAND
registers are rewritten by the following writing to the registers.
Without the change auto negotiation on boot quite often is not
completed in reasonable time:
Waiting for PHY auto negotiation to complete......... TIMEOUT !
Additionally MAC1_SOFT_RESET clear bit is removed since it is done in
preceding lpc32xx_eth_initialize() and in lpc32xx_eth_halt(), instead
added missing MCFG_RESET_MII_MGMT on device initialization.
Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
The lpc32xx_eth_phylib_init() function is capable to connect LPC32XX
MAC to some specified phy by phy id, by chance the single user of
lpc32xx_eth has CONFIG_PHY_ADDR set to 0, however other boards may
have non-zero CONFIG_PHY_ADDR value, fix it.
Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Acked-by: Albert ARIBAUD (3ADEV) <albert.aribaud@3adev.fr>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
According to LPC32x0 User Manual the following bits in Command
register 0x3106_0100 are defined:
Bit Symbol
2 - Unused
3 RegReset
4 TxReset
5 RxReset
Fix wrong (1-bit shifted right) COMMAND_RESETS value, which sets
an unused bit, but neglects RxReset.
Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Acked-by: Albert ARIBAUD (3ADEV) <albert.aribaud@3adev.fr>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
Update the naming convention used in the network stack functions and
variables that Ethernet drivers use to interact with it.
This cleans up the temporary hacks that were added to this interface
along with the DM support.
This patch has a few remaining checkpatch.pl failures that would be out
of the scope of this patch to fix (drivers that are in gross violation
of checkpatch.pl).
Signed-off-by: Joe Hershberger <joe.hershberger@ni.com>
Acked-by: Simon Glass <sjg@chromium.org>