In Errata 1.0.24, if the board is running at OPP50 and has a warm reset,
the boot ROM sets the frequencies for OPP100. This patch attempts to
drop the frequencies back to OPP50 as soon as possible in the SPL. Then
later the voltages and frequencies up set higher.
Cc: Enric Balletbo i Serra <eballetbo@iseebcn.com>
Cc: Lars Poeschel <poeschel@lemonage.de>
Signed-off-by: Steve Kipisz <s-kipisz2@ti.com>
[trini: Adapt to current framework]
Signed-off-by: Tom Rini <trini@ti.com>
Cleaning up the clocks layer.
This helps in addition of new Soc with minimal
changes.
This is derived from OMAP4 boards.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Tested-by: Heiko Schocher <hs@denx.de>
Acked-by: Heiko Schocher <hs@denx.de>
Locking sequence for all the dplls is same.
In the current code same sequence is done repeatedly
for each dpll. Instead have a generic function
for locking dplls and pass dpll data to that function.
This is derived from OMAP4 boards.
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Tested-by: Heiko Schocher <hs@denx.de>
Acked-by: Heiko Schocher <hs@denx.de>
upcoming support for siemens boards switches mpu pll clk in board
code. So make this configurable.
Signed-off-by: Heiko Schocher <hs@denx.de>
Cc: Tom Rini <trini@ti.com>
We must not assume ROM has enabled the clock for MMC1.
Reported-by: Koen Kooi <koen@dominion.thruhere.net>
Signed-off-by: Tom Rini <trini@ti.com>
Acked-by: Peter Korsgaard <jacmet@sunsite.dk>