reset: uniphier: fix compatible for SD reset node for LD11/LD20

LD20 has SD ctrl instead of MIO ctrl.  LD11 has both of them.

Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
This commit is contained in:
Masahiro Yamada 2017-08-29 12:20:50 +09:00
parent d7505752bb
commit 1fc84d6be2

View file

@ -294,7 +294,11 @@ static const struct udevice_id uniphier_reset_match[] = {
.data = (ulong)uniphier_mio_reset_data,
},
{
.compatible = "socionext,uniphier-ld20-mio-reset",
.compatible = "socionext,uniphier-ld11-sd-reset",
.data = (ulong)uniphier_mio_reset_data,
},
{
.compatible = "socionext,uniphier-ld20-sd-reset",
.data = (ulong)uniphier_mio_reset_data,
},
/* Peripheral reset */