imx: ventana: put LTC3676 regulators in continuous mode
In the default pulse-skipping mode regulators that are very lightly loaded can fail to regulate properly. Switching them to always use continuous mode causes only around 10mW of overall system power difference in a lightly loaded system that isn't already operating them in continuous mode. Signed-off-by: Tim Harvey <tharvey@gateworks.com>
This commit is contained in:
parent
722d22813e
commit
0545b17b69
1 changed files with 6 additions and 0 deletions
|
@ -1688,6 +1688,12 @@ void setup_pmic(void)
|
|||
/* set SW3 (VDD_ARM) */
|
||||
pmic_reg_write(p, LTC3676_DVB3A, 0x1f);
|
||||
}
|
||||
|
||||
/* put all switchers in continuous mode */
|
||||
pmic_reg_write(p, LTC3676_BUCK1, 0xc0);
|
||||
pmic_reg_write(p, LTC3676_BUCK2, 0xc0);
|
||||
pmic_reg_write(p, LTC3676_BUCK3, 0xc0);
|
||||
pmic_reg_write(p, LTC3676_BUCK4, 0xc0);
|
||||
}
|
||||
}
|
||||
|
||||
|
|