mirror of
https://github.com/AsahiLinux/u-boot
synced 2024-12-22 11:13:07 +00:00
32 lines
1.2 KiB
Text
32 lines
1.2 KiB
Text
|
SiFive PWM controller
|
||
|
|
||
|
Unlike most other PWM controllers, the SiFive PWM controller currently only
|
||
|
supports one period for all channels in the PWM. All PWMs need to run at
|
||
|
the same period. The period also has significant restrictions on the values
|
||
|
it can achieve, which the driver rounds to the nearest achievable period.
|
||
|
PWM RTL that corresponds to the IP block version numbers can be found
|
||
|
here:
|
||
|
|
||
|
https://github.com/sifive/sifive-blocks/tree/master/src/main/scala/devices/pwm
|
||
|
|
||
|
Required properties:
|
||
|
- compatible: Should be "sifive,<chip>-pwm" and "sifive,pwm<version>".
|
||
|
Supported compatible strings are: "sifive,fu540-c000-pwm" for the SiFive
|
||
|
PWM v0 as integrated onto the SiFive FU540 chip, and "sifive,pwm0" for the
|
||
|
SiFive PWM v0 IP block with no chip integration tweaks.
|
||
|
- reg: physical base address and length of the controller's registers
|
||
|
- clocks: Should contain a clock identifier for the PWM's parent clock.
|
||
|
- #pwm-cells: Should be 3.
|
||
|
- interrupts: one interrupt per PWM channel
|
||
|
|
||
|
Examples:
|
||
|
|
||
|
pwm: pwm@10020000 {
|
||
|
compatible = "sifive,fu540-c000-pwm", "sifive,pwm0";
|
||
|
reg = <0x0 0x10020000 0x0 0x1000>;
|
||
|
clocks = <&tlclk>;
|
||
|
interrupt-parent = <&plic>;
|
||
|
interrupts = <42 43 44 45>;
|
||
|
#pwm-cells = <3>;
|
||
|
};
|