Merge pull request #625 from codemeister64/apcupsd-role

Add Apcupsd role
This commit is contained in:
David Stephens 2024-10-09 21:29:44 +01:00 committed by GitHub
commit 24f4ab4f3e
No known key found for this signature in database
GPG key ID: B5690EEEBB952194
10 changed files with 487 additions and 0 deletions

View file

@ -18,6 +18,7 @@ If you have a spare domain name you can configure applications to be accessible
## Available Applications
* [Airsonic](https://airsonic.github.io/) - catalog and stream music
* [Apcupsd](http://www.apcupsd.org/) - A daemon for controlling APC UPSes
* [Bazarr](https://github.com/morpheus65535/bazarr) - companion to Radarr and Sonarr for downloading subtitles
* [Bitwarden](https://github.com/dani-garcia/vaultwarden) - Password Manger (Technically Vaultwarden, a lightweight implementation in Rust)
* [Booksonic](https://booksonic.org/) - The selfhosted audiobook server

View file

@ -57,6 +57,10 @@
tags:
- airsonic
- role: apcupsd
tags:
- apcupsd
- role: bazarr
tags:
- bazarr

View file

@ -0,0 +1,24 @@
---
apcupsd_enabled: false
# directories
apcupsd_data_directory: "{{ docker_home }}/apcupsd"
# network
apcupsd_port: "3551"
# specs
apcupsd_memory: 1g
# docker
apcupsd_container_name: apcupsd
# ups config
apcupsd_onbatterydelay: 6
apcupsd_batterylevel: 5
apcupsd_minutes: 5
apcupsd_timeout: 0
apcupsd_annoy: 300
apcupsd_annoydelay: 60
apcupsd_nologon: "disable"
apcupsd_killdelay: 0

View file

@ -0,0 +1,6 @@
---
provisioner:
inventory:
group_vars:
all:
apcupsd_enabled: true

View file

@ -0,0 +1,10 @@
---
- name: Stop
hosts: all
become: true
tasks:
- name: "Include {{ lookup('env', 'MOLECULE_PROJECT_DIRECTORY') | basename }} role"
include_role:
name: "{{ lookup('env', 'MOLECULE_PROJECT_DIRECTORY') | basename }}"
vars:
apcupsd_enabled: false

View file

@ -0,0 +1,18 @@
---
- name: Verify
hosts: all
gather_facts: false
tasks:
- include_vars:
file: ../../defaults/main.yml
- name: Get container state
docker_container_info:
name: "{{ apcupsd_container_name }}"
register: result
- name: Check Apcupsd is running
assert:
that:
- result.container['State']['Status'] == "running"
- result.container['State']['Restarting'] == false

View file

@ -0,0 +1,18 @@
---
- name: Verify
hosts: all
gather_facts: false
tasks:
- include_vars:
file: ../../defaults/main.yml
- name: Try and stop and remove Apcupsd
docker_container:
name: "{{ apcupsd_container_name }}"
state: absent
register: result
- name: Check Apcupsd is stopped
assert:
that:
- not result.changed

View file

@ -0,0 +1,48 @@
---
- name: Start Apcupsd
block:
- name: Create Apcupsd Directories
ansible.builtin.file:
path: "{{ item }}"
state: directory
with_items:
- "{{ apcupsd_data_directory }}"
- name: "Check if Apcupsd config exists"
ansible.builtin.stat:
path: "{{ apcupsd_data_directory }}/apcupsd.conf"
register: apcupsd_config_path
- name: Template Apcupsd config
ansible.builtin.template:
src: apcupsd.conf
dest: "{{ apcupsd_data_directory }}/apcupsd.conf"
when: not apcupsd_config_path.stat.exists
- name: Apcupsd Docker Container
community.docker.docker_container:
name: "{{ apcupsd_container_name }}"
image: gregewing/apcupsd
pull: true
privileged: true
volumes:
- "/var/run/dbus/system_bus_socket:/var/run/dbus/system_bus_socket"
- "{{ apcupsd_data_directory }}/apcupsd.conf:/etc/apcupsd/apcupsd.conf"
ports:
- "{{ apcupsd_port }}:3551"
devices:
- "{{ apcupsd_device }}:{{ apcupsd_device }}"
env:
TZ: "{{ ansible_nas_timezone }}"
restart_policy: unless-stopped
memory: "{{ apcupsd_memory }}"
when: apcupsd_enabled is true
- name: Stop Apcupsd
block:
- name: Stop Apcupsd
community.docker.docker_container:
name: "{{ apcupsd_container_name }}"
state: absent
when: apcupsd_enabled is false

View file

@ -0,0 +1,333 @@
## apcupsd.conf v1.1 ##
#
# for apcupsd release 3.14.12 (29 March 2014) - debian
#
# "apcupsd" POSIX config file
#
# ========= General configuration parameters ============
#
# UPSNAME xxx
# Use this to give your UPS a name in log files and such. This
# is particulary useful if you have multiple UPSes. This does not
# set the EEPROM. It should be 8 characters or less.
UPSNAME UPS.host.domain
# UPSCABLE <cable>
# Defines the type of cable connecting the UPS to your computer.
#
# Possible generic choices for <cable> are:
# simple, smart, ether, usb
#
# Or a specific cable model number may be used:
# 940-0119A, 940-0127A, 940-0128A, 940-0020B,
# 940-0020C, 940-0023A, 940-0024B, 940-0024C,
# 940-1524C, 940-0024G, 940-0095A, 940-0095B,
# 940-0095C, 940-0625A, M-04-02-2000
#
UPSCABLE usb
# To get apcupsd to work, in addition to defining the cable
# above, you must also define a UPSTYPE, which corresponds to
# the type of UPS you have (see the Description for more details).
# You must also specify a DEVICE, sometimes referred to as a port.
# For USB UPSes, please leave the DEVICE directive blank. For
# other UPS types, you must specify an appropriate port or address.
#
# UPSTYPE DEVICE Description
# apcsmart /dev/tty** Newer serial character device, appropriate for
# SmartUPS models using a serial cable (not USB).
#
# usb <BLANK> Most new UPSes are USB. A blank DEVICE
# setting enables autodetection, which is
# the best choice for most installations.
#
# net hostname:port Network link to a master apcupsd through apcupsd's
# Network Information Server. This is used if the
# UPS powering your computer is connected to a
# different computer for monitoring.
#
# snmp hostname:port:vendor:community
# SNMP network link to an SNMP-enabled UPS device.
# Hostname is the ip address or hostname of the UPS
# on the network. Vendor can be can be "APC" or
# "APC_NOTRAP". "APC_NOTRAP" will disable SNMP trap
# catching; you usually want "APC". Port is usually
# 161. Community is usually "private".
#
# netsnmp hostname:port:vendor:community
# OBSOLETE
# Same as SNMP above but requires use of the
# net-snmp library. Unless you have a specific need
# for this old driver, you should use 'snmp' instead.
#
# dumb /dev/tty** Old serial character device for use with
# simple-signaling UPSes.
#
# pcnet ipaddr:username:passphrase:port
# PowerChute Network Shutdown protocol which can be
# used as an alternative to SNMP with the AP9617
# family of smart slot cards. ipaddr is the IP
# address of the UPS management card. username and
# passphrase are the credentials for which the card
# has been configured. port is the port number on
# which to listen for messages from the UPS, normally
# 3052. If this parameter is empty or missing, the
# default of 3052 will be used.
#
# modbus /dev/tty** Serial device for use with newest SmartUPS models
# supporting the MODBUS protocol.
#
#UPSTYPE apcsmart
UPSTYPE usb
#DEVICE /dev/ttyS0
# POLLTIME <int>
# Interval (in seconds) at which apcupsd polls the UPS for status. This
# setting applies both to directly-attached UPSes (UPSTYPE apcsmart, usb,
# dumb) and networked UPSes (UPSTYPE net, snmp). Lowering this setting
# will improve apcupsd's responsiveness to certain events at the cost of
# higher CPU utilization. The default of 60 is appropriate for most
# situations.
#POLLTIME 60
# LOCKFILE <path to lockfile>
# Path for device lock file. Not used on Win32.
LOCKFILE /var/lock
# SCRIPTDIR <path to script directory>
# Directory in which apccontrol and event scripts are located.
SCRIPTDIR /etc/apcupsd
# PWRFAILDIR <path to powerfail directory>
# Directory in which to write the powerfail flag file. This file
# is created when apcupsd initiates a system shutdown and is
# checked in the OS halt scripts to determine if a killpower
# (turning off UPS output power) is required.
PWRFAILDIR /etc/apcupsd
# NOLOGINDIR <path to nologin directory>
# Directory in which to write the nologin file. The existence
# of this flag file tells the OS to disallow new logins.
NOLOGINDIR /etc
#
# ======== Configuration parameters used during power failures ==========
#
# The ONBATTERYDELAY is the time in seconds from when a power failure
# is detected until we react to it with an onbattery event.
#
# This means that, apccontrol will be called with the powerout argument
# immediately when a power failure is detected. However, the
# onbattery argument is passed to apccontrol only after the
# ONBATTERYDELAY time. If you don't want to be annoyed by short
# powerfailures, make sure that apccontrol powerout does nothing
# i.e. comment out the wall.
ONBATTERYDELAY {{ apcupsd_onbatterydelay }}
#
# Note: BATTERYLEVEL, MINUTES, and TIMEOUT work in conjunction, so
# the first that occurs will cause the initation of a shutdown.
#
# If during a power failure, the remaining battery percentage
# (as reported by the UPS) is below or equal to BATTERYLEVEL,
# apcupsd will initiate a system shutdown.
BATTERYLEVEL {{ apcupsd_batterylevel }}
# If during a power failure, the remaining runtime in minutes
# (as calculated internally by the UPS) is below or equal to MINUTES,
# apcupsd, will initiate a system shutdown.
MINUTES {{ apcupsd_minutes }}
# If during a power failure, the UPS has run on batteries for TIMEOUT
# many seconds or longer, apcupsd will initiate a system shutdown.
# A value of 0 disables this timer.
#
# Note, if you have a Smart UPS, you will most likely want to disable
# this timer by setting it to zero. That way, you UPS will continue
# on batteries until either the % charge remaing drops to or below BATTERYLEVEL,
# or the remaining battery runtime drops to or below MINUTES. Of course,
# if you are testing, setting this to 60 causes a quick system shutdown
# if you pull the power plug.
# If you have an older dumb UPS, you will want to set this to less than
# the time you know you can run on batteries.
TIMEOUT {{ apcupsd_timeout }}
# Time in seconds between annoying users to signoff prior to
# system shutdown. 0 disables.
ANNOY {{ apcupsd_annoy }}
# Initial delay after power failure before warning users to get
# off the system.
ANNOYDELAY {{ apcupsd_annoydelay }}
# The condition which determines when users are prevented from
# logging in during a power failure.
# NOLOGON <string> [ disable | timeout | percent | minutes | always ]
NOLOGON {{ apcupsd_nologon }}
# If KILLDELAY is non-zero, apcupsd will continue running after a
# shutdown has been requested, and after the specified time in
# seconds attempt to kill the power. This is for use on systems
# where apcupsd cannot regain control after a shutdown.
# KILLDELAY <seconds> 0 disables
KILLDELAY {{ apcupsd_killdelay }}
#
# ==== Configuration statements for Network Information Server ====
#
# NETSERVER [ on | off ] on enables, off disables the network
# information server. If netstatus is on, a network information
# server process will be started for serving the STATUS and
# EVENT data over the network (used by CGI programs).
NETSERVER on
# NISIP <dotted notation ip address>
# IP address on which NIS server will listen for incoming connections.
# This is useful if your server is multi-homed (has more than one
# network interface and IP address). Default value is 0.0.0.0 which
# means any incoming request will be serviced. Alternatively, you can
# configure this setting to any specific IP address of your server and
# NIS will listen for connections only on that interface. Use the
# loopback address (127.0.0.1) to accept connections only from the
# local machine.
NISIP 0.0.0.0
# NISPORT <port> default is 3551 as registered with the IANA
# port to use for sending STATUS and EVENTS data over the network.
# It is not used unless NETSERVER is on. If you change this port,
# you will need to change the corresponding value in the cgi directory
# and rebuild the cgi programs.
NISPORT 3551
# If you want the last few EVENTS to be available over the network
# by the network information server, you must define an EVENTSFILE.
EVENTSFILE /var/log/apcupsd.events
# EVENTSFILEMAX <kilobytes>
# By default, the size of the EVENTSFILE will be not be allowed to exceed
# 10 kilobytes. When the file grows beyond this limit, older EVENTS will
# be removed from the beginning of the file (first in first out). The
# parameter EVENTSFILEMAX can be set to a different kilobyte value, or set
# to zero to allow the EVENTSFILE to grow without limit.
EVENTSFILEMAX 10
#
# ========== Configuration statements used if sharing =============
# a UPS with more than one machine
#
# Remaining items are for ShareUPS (APC expansion card) ONLY
#
# UPSCLASS [ standalone | shareslave | sharemaster ]
# Normally standalone unless you share an UPS using an APC ShareUPS
# card.
UPSCLASS standalone
# UPSMODE [ disable | share ]
# Normally disable unless you share an UPS using an APC ShareUPS card.
UPSMODE disable
#
# ===== Configuration statements to control apcupsd system logging ========
#
# Time interval in seconds between writing the STATUS file; 0 disables
STATTIME 0
# Location of STATUS file (written to only if STATTIME is non-zero)
STATFILE /var/log/apcupsd.status
# LOGSTATS [ on | off ] on enables, off disables
# Note! This generates a lot of output, so if
# you turn this on, be sure that the
# file defined in syslog.conf for LOG_NOTICE is a named pipe.
# You probably do not want this on.
LOGSTATS off
# Time interval in seconds between writing the DATA records to
# the log file. 0 disables.
DATATIME 0
# FACILITY defines the logging facility (class) for logging to syslog.
# If not specified, it defaults to "daemon". This is useful
# if you want to separate the data logged by apcupsd from other
# programs.
#FACILITY DAEMON
#
# ========== Configuration statements used in updating the UPS EPROM =========
#
#
# These statements are used only by apctest when choosing "Set EEPROM with conf
# file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD.
#
# UPS name, max 8 characters
#UPSNAME UPS_IDEN
# Battery date - 8 characters
#BATTDATE mm/dd/yy
# Sensitivity to line voltage quality (H cause faster transfer to batteries)
# SENSITIVITY H M L (default = H)
#SENSITIVITY H
# UPS delay after power return (seconds)
# WAKEUP 000 060 180 300 (default = 0)
#WAKEUP 60
# UPS Grace period after request to power off (seconds)
# SLEEP 020 180 300 600 (default = 20)
#SLEEP 180
# Low line voltage causing transfer to batteries
# The permitted values depend on your model as defined by last letter
# of FIRMWARE or APCMODEL. Some representative values are:
# D 106 103 100 097
# M 177 172 168 182
# A 092 090 088 086
# I 208 204 200 196 (default = 0 => not valid)
#LOTRANSFER 208
# High line voltage causing transfer to batteries
# The permitted values depend on your model as defined by last letter
# of FIRMWARE or APCMODEL. Some representative values are:
# D 127 130 133 136
# M 229 234 239 224
# A 108 110 112 114
# I 253 257 261 265 (default = 0 => not valid)
#HITRANSFER 253
# Battery charge needed to restore power
# RETURNCHARGE 00 15 50 90 (default = 15)
#RETURNCHARGE 15
# Alarm delay
# 0 = zero delay after pwr fail, T = power fail + 30 sec, L = low battery, N = never
# BEEPSTATE 0 T L N (default = 0)
#BEEPSTATE T
# Low battery warning delay in minutes
# LOWBATT 02 05 07 10 (default = 02)
#LOWBATT 2
# UPS Output voltage when running on batteries
# The permitted values depend on your model as defined by last letter
# of FIRMWARE or APCMODEL. Some representative values are:
# D 115
# M 208
# A 100
# I 230 240 220 225 (default = 0 => not valid)
#OUTPUTVOLTS 230
# Self test interval in hours 336=2 weeks, 168=1 week, ON=at power on
# SELFTEST 336 168 ON OFF (default = 336)
#SELFTEST 336

View file

@ -0,0 +1,25 @@
---
title: "Apcupsd"
---
Homepage: [http://www.apcupsd.org/](http://www.apcupsd.org/)
A daemon that manages and monitors a Connected APC UPS Device, which has the ability to gracefully shut down the host computer in the event of a power outage.
## Usage
1. Set `apcupsd_enabled: true` in your `inventories/<your_inventory>/nas.yml` file
2. Set `apcupsd_device` variable to connected UPS device path (e.g `apcupsd_device: "/dev/usb/hiddev0"`) in your `inventories/<your_inventory>/nas.yml` file.
In addition, the following parameters can be overridden in your `inventories/<your_inventory>/nas.yml` file:
* `apcupsd_onbatterydelay` - the time in seconds from when a power failure is detected until we react to it with an onbattery event
* `apcupsd_batterylevel` - if during a power failure, the remaining battery percentage is below or equal to BATTERYLEVEL, apcupsd will initiate a system shutdown
* `apcupsd_minutes` - if during a power failure, the remaining runtime in minutes is below or equal to MINUTES, apcupsd, will initiate a system shutdown
* `apcupsd_timeout` - if during a power failure, the UPS has run on batteries for TIMEOUT many seconds or longer, apcupsd will initiate a system shutdown. A value of 0 disables this timer
* `apcupsd_annoy` - time in seconds between annoying users to signoff prior to system shutdown. 0 disables
* `apcupsd_annoydelay` - initial delay after power failure before warning users to get off the system
* `apcupsd_nologon` - the condition which determines when users are prevented from logging in during a power failure. Possible values: [`disable` | `timeout` | `percent` | `minutes` | `always`]
* `apcupsd_killdelay` - if KILLDELAY is non-zero, apcupsd will continue running after a shutdown has been requested, and after the specified time in seconds attempt to kill the power. This is for use on systems where apcupsd cannot regain control after a shutdown
Apcupsd's exposed netserver default port is 3551, which can be used to collect UPS events and data.