Merge pull request #625 from codemeister64/apcupsd-role
Add Apcupsd role
This commit is contained in:
commit
24f4ab4f3e
10 changed files with 487 additions and 0 deletions
|
@ -18,6 +18,7 @@ If you have a spare domain name you can configure applications to be accessible
|
|||
## Available Applications
|
||||
|
||||
* [Airsonic](https://airsonic.github.io/) - catalog and stream music
|
||||
* [Apcupsd](http://www.apcupsd.org/) - A daemon for controlling APC UPSes
|
||||
* [Bazarr](https://github.com/morpheus65535/bazarr) - companion to Radarr and Sonarr for downloading subtitles
|
||||
* [Bitwarden](https://github.com/dani-garcia/vaultwarden) - Password Manger (Technically Vaultwarden, a lightweight implementation in Rust)
|
||||
* [Booksonic](https://booksonic.org/) - The selfhosted audiobook server
|
||||
|
|
4
nas.yml
4
nas.yml
|
@ -57,6 +57,10 @@
|
|||
tags:
|
||||
- airsonic
|
||||
|
||||
- role: apcupsd
|
||||
tags:
|
||||
- apcupsd
|
||||
|
||||
- role: bazarr
|
||||
tags:
|
||||
- bazarr
|
||||
|
|
24
roles/apcupsd/defaults/main.yml
Normal file
24
roles/apcupsd/defaults/main.yml
Normal file
|
@ -0,0 +1,24 @@
|
|||
---
|
||||
apcupsd_enabled: false
|
||||
|
||||
# directories
|
||||
apcupsd_data_directory: "{{ docker_home }}/apcupsd"
|
||||
|
||||
# network
|
||||
apcupsd_port: "3551"
|
||||
|
||||
# specs
|
||||
apcupsd_memory: 1g
|
||||
|
||||
# docker
|
||||
apcupsd_container_name: apcupsd
|
||||
|
||||
# ups config
|
||||
apcupsd_onbatterydelay: 6
|
||||
apcupsd_batterylevel: 5
|
||||
apcupsd_minutes: 5
|
||||
apcupsd_timeout: 0
|
||||
apcupsd_annoy: 300
|
||||
apcupsd_annoydelay: 60
|
||||
apcupsd_nologon: "disable"
|
||||
apcupsd_killdelay: 0
|
6
roles/apcupsd/molecule/default/molecule.yml
Normal file
6
roles/apcupsd/molecule/default/molecule.yml
Normal file
|
@ -0,0 +1,6 @@
|
|||
---
|
||||
provisioner:
|
||||
inventory:
|
||||
group_vars:
|
||||
all:
|
||||
apcupsd_enabled: true
|
10
roles/apcupsd/molecule/default/side_effect.yml
Normal file
10
roles/apcupsd/molecule/default/side_effect.yml
Normal file
|
@ -0,0 +1,10 @@
|
|||
---
|
||||
- name: Stop
|
||||
hosts: all
|
||||
become: true
|
||||
tasks:
|
||||
- name: "Include {{ lookup('env', 'MOLECULE_PROJECT_DIRECTORY') | basename }} role"
|
||||
include_role:
|
||||
name: "{{ lookup('env', 'MOLECULE_PROJECT_DIRECTORY') | basename }}"
|
||||
vars:
|
||||
apcupsd_enabled: false
|
18
roles/apcupsd/molecule/default/verify.yml
Normal file
18
roles/apcupsd/molecule/default/verify.yml
Normal file
|
@ -0,0 +1,18 @@
|
|||
---
|
||||
- name: Verify
|
||||
hosts: all
|
||||
gather_facts: false
|
||||
tasks:
|
||||
- include_vars:
|
||||
file: ../../defaults/main.yml
|
||||
|
||||
- name: Get container state
|
||||
docker_container_info:
|
||||
name: "{{ apcupsd_container_name }}"
|
||||
register: result
|
||||
|
||||
- name: Check Apcupsd is running
|
||||
assert:
|
||||
that:
|
||||
- result.container['State']['Status'] == "running"
|
||||
- result.container['State']['Restarting'] == false
|
18
roles/apcupsd/molecule/default/verify_stopped.yml
Normal file
18
roles/apcupsd/molecule/default/verify_stopped.yml
Normal file
|
@ -0,0 +1,18 @@
|
|||
---
|
||||
- name: Verify
|
||||
hosts: all
|
||||
gather_facts: false
|
||||
tasks:
|
||||
- include_vars:
|
||||
file: ../../defaults/main.yml
|
||||
|
||||
- name: Try and stop and remove Apcupsd
|
||||
docker_container:
|
||||
name: "{{ apcupsd_container_name }}"
|
||||
state: absent
|
||||
register: result
|
||||
|
||||
- name: Check Apcupsd is stopped
|
||||
assert:
|
||||
that:
|
||||
- not result.changed
|
48
roles/apcupsd/tasks/main.yml
Normal file
48
roles/apcupsd/tasks/main.yml
Normal file
|
@ -0,0 +1,48 @@
|
|||
---
|
||||
|
||||
- name: Start Apcupsd
|
||||
block:
|
||||
- name: Create Apcupsd Directories
|
||||
ansible.builtin.file:
|
||||
path: "{{ item }}"
|
||||
state: directory
|
||||
with_items:
|
||||
- "{{ apcupsd_data_directory }}"
|
||||
|
||||
- name: "Check if Apcupsd config exists"
|
||||
ansible.builtin.stat:
|
||||
path: "{{ apcupsd_data_directory }}/apcupsd.conf"
|
||||
register: apcupsd_config_path
|
||||
|
||||
- name: Template Apcupsd config
|
||||
ansible.builtin.template:
|
||||
src: apcupsd.conf
|
||||
dest: "{{ apcupsd_data_directory }}/apcupsd.conf"
|
||||
when: not apcupsd_config_path.stat.exists
|
||||
|
||||
- name: Apcupsd Docker Container
|
||||
community.docker.docker_container:
|
||||
name: "{{ apcupsd_container_name }}"
|
||||
image: gregewing/apcupsd
|
||||
pull: true
|
||||
privileged: true
|
||||
volumes:
|
||||
- "/var/run/dbus/system_bus_socket:/var/run/dbus/system_bus_socket"
|
||||
- "{{ apcupsd_data_directory }}/apcupsd.conf:/etc/apcupsd/apcupsd.conf"
|
||||
ports:
|
||||
- "{{ apcupsd_port }}:3551"
|
||||
devices:
|
||||
- "{{ apcupsd_device }}:{{ apcupsd_device }}"
|
||||
env:
|
||||
TZ: "{{ ansible_nas_timezone }}"
|
||||
restart_policy: unless-stopped
|
||||
memory: "{{ apcupsd_memory }}"
|
||||
when: apcupsd_enabled is true
|
||||
|
||||
- name: Stop Apcupsd
|
||||
block:
|
||||
- name: Stop Apcupsd
|
||||
community.docker.docker_container:
|
||||
name: "{{ apcupsd_container_name }}"
|
||||
state: absent
|
||||
when: apcupsd_enabled is false
|
333
roles/apcupsd/templates/apcupsd.conf
Normal file
333
roles/apcupsd/templates/apcupsd.conf
Normal file
|
@ -0,0 +1,333 @@
|
|||
## apcupsd.conf v1.1 ##
|
||||
#
|
||||
# for apcupsd release 3.14.12 (29 March 2014) - debian
|
||||
#
|
||||
# "apcupsd" POSIX config file
|
||||
|
||||
#
|
||||
# ========= General configuration parameters ============
|
||||
#
|
||||
|
||||
# UPSNAME xxx
|
||||
# Use this to give your UPS a name in log files and such. This
|
||||
# is particulary useful if you have multiple UPSes. This does not
|
||||
# set the EEPROM. It should be 8 characters or less.
|
||||
UPSNAME UPS.host.domain
|
||||
|
||||
# UPSCABLE <cable>
|
||||
# Defines the type of cable connecting the UPS to your computer.
|
||||
#
|
||||
# Possible generic choices for <cable> are:
|
||||
# simple, smart, ether, usb
|
||||
#
|
||||
# Or a specific cable model number may be used:
|
||||
# 940-0119A, 940-0127A, 940-0128A, 940-0020B,
|
||||
# 940-0020C, 940-0023A, 940-0024B, 940-0024C,
|
||||
# 940-1524C, 940-0024G, 940-0095A, 940-0095B,
|
||||
# 940-0095C, 940-0625A, M-04-02-2000
|
||||
#
|
||||
UPSCABLE usb
|
||||
|
||||
# To get apcupsd to work, in addition to defining the cable
|
||||
# above, you must also define a UPSTYPE, which corresponds to
|
||||
# the type of UPS you have (see the Description for more details).
|
||||
# You must also specify a DEVICE, sometimes referred to as a port.
|
||||
# For USB UPSes, please leave the DEVICE directive blank. For
|
||||
# other UPS types, you must specify an appropriate port or address.
|
||||
#
|
||||
# UPSTYPE DEVICE Description
|
||||
# apcsmart /dev/tty** Newer serial character device, appropriate for
|
||||
# SmartUPS models using a serial cable (not USB).
|
||||
#
|
||||
# usb <BLANK> Most new UPSes are USB. A blank DEVICE
|
||||
# setting enables autodetection, which is
|
||||
# the best choice for most installations.
|
||||
#
|
||||
# net hostname:port Network link to a master apcupsd through apcupsd's
|
||||
# Network Information Server. This is used if the
|
||||
# UPS powering your computer is connected to a
|
||||
# different computer for monitoring.
|
||||
#
|
||||
# snmp hostname:port:vendor:community
|
||||
# SNMP network link to an SNMP-enabled UPS device.
|
||||
# Hostname is the ip address or hostname of the UPS
|
||||
# on the network. Vendor can be can be "APC" or
|
||||
# "APC_NOTRAP". "APC_NOTRAP" will disable SNMP trap
|
||||
# catching; you usually want "APC". Port is usually
|
||||
# 161. Community is usually "private".
|
||||
#
|
||||
# netsnmp hostname:port:vendor:community
|
||||
# OBSOLETE
|
||||
# Same as SNMP above but requires use of the
|
||||
# net-snmp library. Unless you have a specific need
|
||||
# for this old driver, you should use 'snmp' instead.
|
||||
#
|
||||
# dumb /dev/tty** Old serial character device for use with
|
||||
# simple-signaling UPSes.
|
||||
#
|
||||
# pcnet ipaddr:username:passphrase:port
|
||||
# PowerChute Network Shutdown protocol which can be
|
||||
# used as an alternative to SNMP with the AP9617
|
||||
# family of smart slot cards. ipaddr is the IP
|
||||
# address of the UPS management card. username and
|
||||
# passphrase are the credentials for which the card
|
||||
# has been configured. port is the port number on
|
||||
# which to listen for messages from the UPS, normally
|
||||
# 3052. If this parameter is empty or missing, the
|
||||
# default of 3052 will be used.
|
||||
#
|
||||
# modbus /dev/tty** Serial device for use with newest SmartUPS models
|
||||
# supporting the MODBUS protocol.
|
||||
#
|
||||
#UPSTYPE apcsmart
|
||||
UPSTYPE usb
|
||||
#DEVICE /dev/ttyS0
|
||||
|
||||
# POLLTIME <int>
|
||||
# Interval (in seconds) at which apcupsd polls the UPS for status. This
|
||||
# setting applies both to directly-attached UPSes (UPSTYPE apcsmart, usb,
|
||||
# dumb) and networked UPSes (UPSTYPE net, snmp). Lowering this setting
|
||||
# will improve apcupsd's responsiveness to certain events at the cost of
|
||||
# higher CPU utilization. The default of 60 is appropriate for most
|
||||
# situations.
|
||||
#POLLTIME 60
|
||||
|
||||
# LOCKFILE <path to lockfile>
|
||||
# Path for device lock file. Not used on Win32.
|
||||
LOCKFILE /var/lock
|
||||
|
||||
# SCRIPTDIR <path to script directory>
|
||||
# Directory in which apccontrol and event scripts are located.
|
||||
SCRIPTDIR /etc/apcupsd
|
||||
|
||||
# PWRFAILDIR <path to powerfail directory>
|
||||
# Directory in which to write the powerfail flag file. This file
|
||||
# is created when apcupsd initiates a system shutdown and is
|
||||
# checked in the OS halt scripts to determine if a killpower
|
||||
# (turning off UPS output power) is required.
|
||||
PWRFAILDIR /etc/apcupsd
|
||||
|
||||
# NOLOGINDIR <path to nologin directory>
|
||||
# Directory in which to write the nologin file. The existence
|
||||
# of this flag file tells the OS to disallow new logins.
|
||||
NOLOGINDIR /etc
|
||||
|
||||
|
||||
#
|
||||
# ======== Configuration parameters used during power failures ==========
|
||||
#
|
||||
|
||||
# The ONBATTERYDELAY is the time in seconds from when a power failure
|
||||
# is detected until we react to it with an onbattery event.
|
||||
#
|
||||
# This means that, apccontrol will be called with the powerout argument
|
||||
# immediately when a power failure is detected. However, the
|
||||
# onbattery argument is passed to apccontrol only after the
|
||||
# ONBATTERYDELAY time. If you don't want to be annoyed by short
|
||||
# powerfailures, make sure that apccontrol powerout does nothing
|
||||
# i.e. comment out the wall.
|
||||
ONBATTERYDELAY {{ apcupsd_onbatterydelay }}
|
||||
|
||||
#
|
||||
# Note: BATTERYLEVEL, MINUTES, and TIMEOUT work in conjunction, so
|
||||
# the first that occurs will cause the initation of a shutdown.
|
||||
#
|
||||
|
||||
# If during a power failure, the remaining battery percentage
|
||||
# (as reported by the UPS) is below or equal to BATTERYLEVEL,
|
||||
# apcupsd will initiate a system shutdown.
|
||||
BATTERYLEVEL {{ apcupsd_batterylevel }}
|
||||
|
||||
# If during a power failure, the remaining runtime in minutes
|
||||
# (as calculated internally by the UPS) is below or equal to MINUTES,
|
||||
# apcupsd, will initiate a system shutdown.
|
||||
MINUTES {{ apcupsd_minutes }}
|
||||
|
||||
# If during a power failure, the UPS has run on batteries for TIMEOUT
|
||||
# many seconds or longer, apcupsd will initiate a system shutdown.
|
||||
# A value of 0 disables this timer.
|
||||
#
|
||||
# Note, if you have a Smart UPS, you will most likely want to disable
|
||||
# this timer by setting it to zero. That way, you UPS will continue
|
||||
# on batteries until either the % charge remaing drops to or below BATTERYLEVEL,
|
||||
# or the remaining battery runtime drops to or below MINUTES. Of course,
|
||||
# if you are testing, setting this to 60 causes a quick system shutdown
|
||||
# if you pull the power plug.
|
||||
# If you have an older dumb UPS, you will want to set this to less than
|
||||
# the time you know you can run on batteries.
|
||||
TIMEOUT {{ apcupsd_timeout }}
|
||||
|
||||
# Time in seconds between annoying users to signoff prior to
|
||||
# system shutdown. 0 disables.
|
||||
ANNOY {{ apcupsd_annoy }}
|
||||
|
||||
# Initial delay after power failure before warning users to get
|
||||
# off the system.
|
||||
ANNOYDELAY {{ apcupsd_annoydelay }}
|
||||
|
||||
# The condition which determines when users are prevented from
|
||||
# logging in during a power failure.
|
||||
# NOLOGON <string> [ disable | timeout | percent | minutes | always ]
|
||||
NOLOGON {{ apcupsd_nologon }}
|
||||
|
||||
# If KILLDELAY is non-zero, apcupsd will continue running after a
|
||||
# shutdown has been requested, and after the specified time in
|
||||
# seconds attempt to kill the power. This is for use on systems
|
||||
# where apcupsd cannot regain control after a shutdown.
|
||||
# KILLDELAY <seconds> 0 disables
|
||||
KILLDELAY {{ apcupsd_killdelay }}
|
||||
|
||||
#
|
||||
# ==== Configuration statements for Network Information Server ====
|
||||
#
|
||||
|
||||
# NETSERVER [ on | off ] on enables, off disables the network
|
||||
# information server. If netstatus is on, a network information
|
||||
# server process will be started for serving the STATUS and
|
||||
# EVENT data over the network (used by CGI programs).
|
||||
NETSERVER on
|
||||
|
||||
# NISIP <dotted notation ip address>
|
||||
# IP address on which NIS server will listen for incoming connections.
|
||||
# This is useful if your server is multi-homed (has more than one
|
||||
# network interface and IP address). Default value is 0.0.0.0 which
|
||||
# means any incoming request will be serviced. Alternatively, you can
|
||||
# configure this setting to any specific IP address of your server and
|
||||
# NIS will listen for connections only on that interface. Use the
|
||||
# loopback address (127.0.0.1) to accept connections only from the
|
||||
# local machine.
|
||||
NISIP 0.0.0.0
|
||||
|
||||
# NISPORT <port> default is 3551 as registered with the IANA
|
||||
# port to use for sending STATUS and EVENTS data over the network.
|
||||
# It is not used unless NETSERVER is on. If you change this port,
|
||||
# you will need to change the corresponding value in the cgi directory
|
||||
# and rebuild the cgi programs.
|
||||
NISPORT 3551
|
||||
|
||||
# If you want the last few EVENTS to be available over the network
|
||||
# by the network information server, you must define an EVENTSFILE.
|
||||
EVENTSFILE /var/log/apcupsd.events
|
||||
|
||||
# EVENTSFILEMAX <kilobytes>
|
||||
# By default, the size of the EVENTSFILE will be not be allowed to exceed
|
||||
# 10 kilobytes. When the file grows beyond this limit, older EVENTS will
|
||||
# be removed from the beginning of the file (first in first out). The
|
||||
# parameter EVENTSFILEMAX can be set to a different kilobyte value, or set
|
||||
# to zero to allow the EVENTSFILE to grow without limit.
|
||||
EVENTSFILEMAX 10
|
||||
|
||||
#
|
||||
# ========== Configuration statements used if sharing =============
|
||||
# a UPS with more than one machine
|
||||
|
||||
#
|
||||
# Remaining items are for ShareUPS (APC expansion card) ONLY
|
||||
#
|
||||
|
||||
# UPSCLASS [ standalone | shareslave | sharemaster ]
|
||||
# Normally standalone unless you share an UPS using an APC ShareUPS
|
||||
# card.
|
||||
UPSCLASS standalone
|
||||
|
||||
# UPSMODE [ disable | share ]
|
||||
# Normally disable unless you share an UPS using an APC ShareUPS card.
|
||||
UPSMODE disable
|
||||
|
||||
#
|
||||
# ===== Configuration statements to control apcupsd system logging ========
|
||||
#
|
||||
|
||||
# Time interval in seconds between writing the STATUS file; 0 disables
|
||||
STATTIME 0
|
||||
|
||||
# Location of STATUS file (written to only if STATTIME is non-zero)
|
||||
STATFILE /var/log/apcupsd.status
|
||||
|
||||
# LOGSTATS [ on | off ] on enables, off disables
|
||||
# Note! This generates a lot of output, so if
|
||||
# you turn this on, be sure that the
|
||||
# file defined in syslog.conf for LOG_NOTICE is a named pipe.
|
||||
# You probably do not want this on.
|
||||
LOGSTATS off
|
||||
|
||||
# Time interval in seconds between writing the DATA records to
|
||||
# the log file. 0 disables.
|
||||
DATATIME 0
|
||||
|
||||
# FACILITY defines the logging facility (class) for logging to syslog.
|
||||
# If not specified, it defaults to "daemon". This is useful
|
||||
# if you want to separate the data logged by apcupsd from other
|
||||
# programs.
|
||||
#FACILITY DAEMON
|
||||
|
||||
#
|
||||
# ========== Configuration statements used in updating the UPS EPROM =========
|
||||
#
|
||||
|
||||
#
|
||||
# These statements are used only by apctest when choosing "Set EEPROM with conf
|
||||
# file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD.
|
||||
#
|
||||
|
||||
# UPS name, max 8 characters
|
||||
#UPSNAME UPS_IDEN
|
||||
|
||||
# Battery date - 8 characters
|
||||
#BATTDATE mm/dd/yy
|
||||
|
||||
# Sensitivity to line voltage quality (H cause faster transfer to batteries)
|
||||
# SENSITIVITY H M L (default = H)
|
||||
#SENSITIVITY H
|
||||
|
||||
# UPS delay after power return (seconds)
|
||||
# WAKEUP 000 060 180 300 (default = 0)
|
||||
#WAKEUP 60
|
||||
|
||||
# UPS Grace period after request to power off (seconds)
|
||||
# SLEEP 020 180 300 600 (default = 20)
|
||||
#SLEEP 180
|
||||
|
||||
# Low line voltage causing transfer to batteries
|
||||
# The permitted values depend on your model as defined by last letter
|
||||
# of FIRMWARE or APCMODEL. Some representative values are:
|
||||
# D 106 103 100 097
|
||||
# M 177 172 168 182
|
||||
# A 092 090 088 086
|
||||
# I 208 204 200 196 (default = 0 => not valid)
|
||||
#LOTRANSFER 208
|
||||
|
||||
# High line voltage causing transfer to batteries
|
||||
# The permitted values depend on your model as defined by last letter
|
||||
# of FIRMWARE or APCMODEL. Some representative values are:
|
||||
# D 127 130 133 136
|
||||
# M 229 234 239 224
|
||||
# A 108 110 112 114
|
||||
# I 253 257 261 265 (default = 0 => not valid)
|
||||
#HITRANSFER 253
|
||||
|
||||
# Battery charge needed to restore power
|
||||
# RETURNCHARGE 00 15 50 90 (default = 15)
|
||||
#RETURNCHARGE 15
|
||||
|
||||
# Alarm delay
|
||||
# 0 = zero delay after pwr fail, T = power fail + 30 sec, L = low battery, N = never
|
||||
# BEEPSTATE 0 T L N (default = 0)
|
||||
#BEEPSTATE T
|
||||
|
||||
# Low battery warning delay in minutes
|
||||
# LOWBATT 02 05 07 10 (default = 02)
|
||||
#LOWBATT 2
|
||||
|
||||
# UPS Output voltage when running on batteries
|
||||
# The permitted values depend on your model as defined by last letter
|
||||
# of FIRMWARE or APCMODEL. Some representative values are:
|
||||
# D 115
|
||||
# M 208
|
||||
# A 100
|
||||
# I 230 240 220 225 (default = 0 => not valid)
|
||||
#OUTPUTVOLTS 230
|
||||
|
||||
# Self test interval in hours 336=2 weeks, 168=1 week, ON=at power on
|
||||
# SELFTEST 336 168 ON OFF (default = 336)
|
||||
#SELFTEST 336
|
25
website/docs/applications/system-tools/apcupsd.md
Normal file
25
website/docs/applications/system-tools/apcupsd.md
Normal file
|
@ -0,0 +1,25 @@
|
|||
---
|
||||
title: "Apcupsd"
|
||||
---
|
||||
|
||||
Homepage: [http://www.apcupsd.org/](http://www.apcupsd.org/)
|
||||
|
||||
A daemon that manages and monitors a Connected APC UPS Device, which has the ability to gracefully shut down the host computer in the event of a power outage.
|
||||
|
||||
## Usage
|
||||
|
||||
1. Set `apcupsd_enabled: true` in your `inventories/<your_inventory>/nas.yml` file
|
||||
2. Set `apcupsd_device` variable to connected UPS device path (e.g `apcupsd_device: "/dev/usb/hiddev0"`) in your `inventories/<your_inventory>/nas.yml` file.
|
||||
|
||||
In addition, the following parameters can be overridden in your `inventories/<your_inventory>/nas.yml` file:
|
||||
|
||||
* `apcupsd_onbatterydelay` - the time in seconds from when a power failure is detected until we react to it with an onbattery event
|
||||
* `apcupsd_batterylevel` - if during a power failure, the remaining battery percentage is below or equal to BATTERYLEVEL, apcupsd will initiate a system shutdown
|
||||
* `apcupsd_minutes` - if during a power failure, the remaining runtime in minutes is below or equal to MINUTES, apcupsd, will initiate a system shutdown
|
||||
* `apcupsd_timeout` - if during a power failure, the UPS has run on batteries for TIMEOUT many seconds or longer, apcupsd will initiate a system shutdown. A value of 0 disables this timer
|
||||
* `apcupsd_annoy` - time in seconds between annoying users to signoff prior to system shutdown. 0 disables
|
||||
* `apcupsd_annoydelay` - initial delay after power failure before warning users to get off the system
|
||||
* `apcupsd_nologon` - the condition which determines when users are prevented from logging in during a power failure. Possible values: [`disable` | `timeout` | `percent` | `minutes` | `always`]
|
||||
* `apcupsd_killdelay` - if KILLDELAY is non-zero, apcupsd will continue running after a shutdown has been requested, and after the specified time in seconds attempt to kill the power. This is for use on systems where apcupsd cannot regain control after a shutdown
|
||||
|
||||
Apcupsd's exposed netserver default port is 3551, which can be used to collect UPS events and data.
|