PKHeX/PKHeX.WinForms/Program.cs
Kurt de6c1baaf2 Minor tweaks
PK9: Fix writing box bin of self-owned SV eggs clearing nickname trash, also clear any hint of trading completely
SAV1: ensure current box is index:0 if uninitialized
2024-06-05 23:46:03 -05:00

189 lines
6.9 KiB
C#

using System;
using System.Threading.Tasks;
using System.Windows.Forms;
using PKHeX.Core;
#if !DEBUG
using System.Reflection;
using System.IO;
using System.Threading;
#endif
namespace PKHeX.WinForms;
internal static class Program
{
/// <summary>
/// The main entry point for the application.
/// </summary>
[STAThread]
private static void Main()
{
#if !DEBUG
// Add the event handler for handling UI thread exceptions to the event.
Application.ThreadException += UIThreadException;
// Set the unhandled exception mode to force all Windows Forms errors to go through our handler.
Application.SetUnhandledExceptionMode(UnhandledExceptionMode.CatchException);
// Add the event handler for handling non-UI thread exceptions to the event.
AppDomain.CurrentDomain.UnhandledException += CurrentDomain_UnhandledException;
#endif
// Run the application
Application.EnableVisualStyles();
Application.SetCompatibleTextRenderingDefault(false);
var splash = new SplashScreen();
new Task(() => splash.ShowDialog()).Start();
new Task(() => EncounterEvent.RefreshMGDB(WinForms.Main.MGDatabasePath)).Start();
var main = new Main();
splash.BeginInvoke(splash.ForceClose);
Application.Run(main);
}
// Pipelines build can sometimes tack on text to the version code. Strip it out.
public static readonly Version CurrentVersion = Version.Parse(GetSaneVersionTag(Application.ProductVersion));
private static ReadOnlySpan<char> GetSaneVersionTag(ReadOnlySpan<char> productVersion)
{
// Take only 0-9 and '.', stop on first char not in that set.
for (int i = 0; i < productVersion.Length; i++)
{
char c = productVersion[i];
if (c == '.')
continue;
if (char.IsNumber(c))
continue;
return productVersion[..i];
}
return productVersion;
}
#if !DEBUG
private static void Error(string msg) => MessageBox.Show(msg, "PKHeX Error", MessageBoxButtons.OK, MessageBoxIcon.Stop);
// Handle the UI exceptions by showing a dialog box, and asking the user if they wish to abort execution.
private static void UIThreadException(object sender, ThreadExceptionEventArgs t)
{
DialogResult result = DialogResult.Cancel;
try
{
var e = t.Exception;
string errorMessage = GetErrorMessage(e);
result = ErrorWindow.ShowErrorDialog(errorMessage, e, true);
}
catch (Exception reportingException)
{
HandleReportingException(t.Exception, reportingException);
}
// Exits the program when the user clicks Abort.
if (result == DialogResult.Abort)
Application.Exit();
}
private static string GetErrorMessage(Exception e)
{
return IsPluginError<IPlugin>(e, out var pluginName)
? $"An error occurred in a PKHeX plugin. Please report this error to the plugin author/maintainer.\n{pluginName}"
: "An error occurred in PKHeX. Please report this error to the PKHeX author.";
}
// Handle the UI exceptions by showing a dialog box, and asking the user if they wish to abort execution.
// NOTE: This exception cannot be kept from terminating the application - it can only
// log the event, and inform the user about it.
private static void CurrentDomain_UnhandledException(object sender, UnhandledExceptionEventArgs e)
{
var ex = e.ExceptionObject as Exception;
try
{
if (IsOldPkhexCorePresent(ex))
{
Error("You have upgraded PKHeX incorrectly. Please delete PKHeX.Core.dll.");
}
else if (ex != null)
{
var msg = GetErrorMessage(ex);
ErrorWindow.ShowErrorDialog($"{msg}\nPKHeX must now close.", ex, false);
}
else
{
Error("A fatal non-UI error has occurred in PKHeX, and the details could not be displayed. Please report this to the author.");
}
}
catch (Exception reportingException)
{
HandleReportingException(ex, reportingException);
}
}
private static bool IsPluginError<T>(Exception exception, out string pluginName)
{
// Check the stacktrace to see if the namespace is a type that derives from IPlugin
pluginName = string.Empty;
var stackTrace = new System.Diagnostics.StackTrace(exception);
foreach (var frame in stackTrace.GetFrames())
{
var method = frame.GetMethod();
var type = method?.DeclaringType;
if (!typeof(T).IsAssignableFrom(type))
continue;
pluginName = type.Namespace ?? string.Empty;
return true;
}
return false;
}
private static void HandleReportingException(Exception? ex, Exception reportingException)
{
try
{
EmergencyErrorLog(ex, reportingException);
}
catch
{
// We've failed to even save the error details to a file. There's nothing else we can do.
}
if (reportingException is FileNotFoundException x && x.FileName?.StartsWith("PKHeX.Core") == true)
{
Error("Could not locate PKHeX.Core.dll. Make sure you're running PKHeX together with its code library. Usually caused when all files are not extracted.");
return;
}
try
{
Error("A fatal non-UI error has occurred in PKHeX, and there was a problem displaying the details. Please report this to the author.");
}
finally
{
Application.Exit();
}
}
/// <summary>
/// Attempt to log exceptions to a file when there's an error displaying exception details.
/// </summary>
/// <param name="originalException"></param>
/// <param name="errorHandlingException"></param>
private static bool EmergencyErrorLog(Exception? originalException, Exception errorHandlingException)
{
try
{
// Not using a string builder because something's very wrong, and we don't want to make things worse
var message = (originalException?.ToString() ?? "null first exception") + Environment.NewLine + errorHandlingException;
File.WriteAllText($"PKHeX_Error_Report {DateTime.Now:yyyyMMddHHmmss}.txt", message);
}
catch (Exception)
{
// We've failed to save the error details twice now. There's nothing else we can do.
return false;
}
return true;
}
private static bool IsOldPkhexCorePresent(Exception? ex)
{
return ex is MissingMethodException or TypeLoadException or TypeInitializationException
&& File.Exists("PKHeX.Core.dll")
&& AssemblyName.GetAssemblyName("PKHeX.Core.dll").Version < CurrentVersion;
}
#endif
}